Search found 28 matches

by turbofergy
Tue May 28, 2019 12:49 pm
Forum: Hydraulic Design
Topic: Cut Lasso not working
Replies: 1
Views: 151

Cut Lasso not working

Hi

In irricad v16 i am trying to use cut lasso to cut tapes in a drain however the beginning of the lasso will not position where the cross hairs are and scrolling the drawing in and out the cut lasso lines do not stay where they were placed.

Thanks

Kyle
by turbofergy
Tue May 28, 2019 11:44 am
Forum: Hydraulic Design
Topic: Irricad Link - Large Negative Z values
Replies: 1
Views: 223

Irricad Link - Large Negative Z values

Hello All

Setting out a block in Link. When i put in a cut pipe for a sub main the nodes are getting very large negative Z values (-1000000.00). I am not sure where they are coming from. When i look at the 3D DEM the heights are are all correct. is there a way to correct this

Regards

Kyle
by turbofergy
Fri Apr 05, 2019 2:58 pm
Forum: Miscellaneous
Topic: Link licence transfer
Replies: 8
Views: 559

Re: Link licence transfer

Dan

The above were true and the registry was correct.

Thanks

kyle
by turbofergy
Fri Apr 05, 2019 10:45 am
Forum: Miscellaneous
Topic: Link licence transfer
Replies: 8
Views: 559

Re: Link licence transfer

Dan

Thanks for the quick reply. i have tried running 18 but it still says that 18 in not installed on the computer.

Thanks

Kyle
by turbofergy
Fri Apr 05, 2019 10:09 am
Forum: Miscellaneous
Topic: Link licence transfer
Replies: 8
Views: 559

Re: Link licence transfer

Phil

When i changed computers i upgraded to v19 Bricscad. I also still have v18 installed however the software will not install. Any ideas what might be the issue

Thanks

Kyle
by turbofergy
Thu Apr 04, 2019 9:22 am
Forum: Miscellaneous
Topic: Link licence transfer
Replies: 8
Views: 559

Link licence transfer

Hello

I am changing computers and was wondering how to transfer my Irricad Link licence.

Thanks
by turbofergy
Tue Dec 11, 2018 8:29 am
Forum: Miscellaneous
Topic: Fittings Label
Replies: 1
Views: 532

Fittings Label

Hi

Is there a method for getting fittings listed at a mainline node to display a label.

Thanks

Kyle
by turbofergy
Tue Nov 27, 2018 4:39 pm
Forum: Importing and Exporting
Topic: Import Ht errors
Replies: 1
Views: 572

Import Ht errors

Hello I am trying to import some GPS data into Irricad but the elevation is not importing correctly. It has an elevation hundreds of meters more than it should. I have tried several import formats (CSV, SHP and DXF). The data is correct in the CSV and strangely is imports fine into Irricad Link. Any...
by turbofergy
Tue Nov 20, 2018 8:16 pm
Forum: Miscellaneous
Topic: Shift delete Irricad Link
Replies: 1
Views: 567

Shift delete Irricad Link

Hi

The handy SHIFT + DELETE for deleting multiple spray lines does not work in Irricad link. is there another method.

Thanks

Kyle
by turbofergy
Fri Oct 12, 2018 5:27 pm
Forum: Miscellaneous
Topic: Templates Irricad Link
Replies: 2
Views: 703

Re: Templates Irricad Link

Thanks Jo
by turbofergy
Thu Oct 11, 2018 1:36 pm
Forum: Miscellaneous
Topic: Templates Irricad Link
Replies: 2
Views: 703

Templates Irricad Link

Hello

Currently the templates provided in Irricad link only work in landscape. is there anyway of getting them to work in portrait.

Also a dedicated 'link' forum on the forum page would be good.

Thanks

Kyle
by turbofergy
Wed Oct 03, 2018 4:47 pm
Forum: Miscellaneous
Topic: DBS 4
Replies: 2
Views: 667

Re: DBS 4

Jo

Thanks for you fast reply. i am using the latest patch. I will delete temp folder. i had navigated there but did not want to hastily delete anything.

Thanks

KYle
by turbofergy
Wed Oct 03, 2018 4:11 pm
Forum: Miscellaneous
Topic: DBS 4
Replies: 2
Views: 667

DBS 4

Hi I am having an error message appear when I try to save in Link. I get a message saying Please note: DBS 4 Database could not be created Renaming C: The process cannot access the file because it is being used by another process. I have turned everything off and restarted the computer twice but to ...
by turbofergy
Sun Sep 16, 2018 9:07 pm
Forum: Hydraulic Design
Topic: DES 443
Replies: 1
Views: 638

DES 443

Hello

I am currently doing a design and am having a few blocks come up with DES 443 when performing the LP analysis. This is not a warning I have had in the past and am not sure how to solve for it. As I am asking the program to solve the sub-main sizing is it unsolvable?

Thanks

Kyle
by turbofergy
Thu Sep 13, 2018 8:01 am
Forum: Hydraulic Design
Topic: Moving a sub-main
Replies: 1
Views: 612

Moving a sub-main

Hello

I would like to move a submain a few meters down a block to try and even out some pressures. Is there an easy way to do this.

Thanks

Kyle
by turbofergy
Tue Sep 11, 2018 1:13 pm
Forum: Hydraulic Design
Topic: Sub dividing block
Replies: 1
Views: 646

Sub dividing block

Hello

Sub-divided a block and irricad is not allowing me to sub-divide one of the blocks again. Every time I click on the new boundary and click subdivide I get a message saying the subdivision tool only works on block entities. I am sure I have sub-divided a subdivision in the past.

Kyle
by turbofergy
Fri Sep 07, 2018 6:38 pm
Forum: Miscellaneous
Topic: Reports on Irricad Link
Replies: 2
Views: 811

Reports on Irricad Link

Hello

I transferred some custom zone reports into the irricad link folder for use in zone design. They worked fine however have now disappeared from the report options menus however still exist in the irricad link folder. I have tried deleting and re-installing but no luck.

Any thoughts

Kyle
by turbofergy
Wed Aug 29, 2018 6:54 pm
Forum: Hydraulic Design
Topic: cutting tapes
Replies: 4
Views: 996

Re: cutting tapes

Jo

The cut Lasso worked well however i cant delete the small section of pipe in the drain. Any suggestions?

Kyle
by turbofergy
Thu Aug 23, 2018 5:39 pm
Forum: Hydraulic Design
Topic: cutting tapes
Replies: 4
Views: 996

Re: cutting tapes

Jo

Thanks for your reply. Cut lasso was what i was looking for. Due to the drain line and the block configuration the latter option was not aligning properly on either side of the drain.

Thanks

Kyle
by turbofergy
Thu Aug 23, 2018 9:59 am
Forum: Hydraulic Design
Topic: cutting tapes
Replies: 4
Views: 996

cutting tapes

Hello

I have a large block that is split by an angular drain through one end. The farm manager wants to cut the tape along the drain. is there a method of making the whole block a tape entity and laying out the lands and headlands then cutting the tapes (spraylines) to suit.

Thanks

Kyle