Search found 69 matches
- Fri Oct 04, 2024 10:31 am
- Forum: Hydraulic Design
- Topic: Flushing manifold - automatically place the vacuum breaker at high elevation.
- Replies: 3
- Views: 3107
- Tue Aug 29, 2023 11:30 am
- Forum: Suggestions
- Topic: Simulate Multiple lateral functions
- Replies: 2
- Views: 5928
Simulate Multiple lateral functions
Hi Irricad Team
It would be great to implement a feature where we could model multiple laterals within any block entity.
For example. Design 1 has been completed, 6m row spacing, two laterals per row, with both laterals a nominal dripline lateral (Type 1) of 1.6lph @ 0.5m.
If an alternative ...
It would be great to implement a feature where we could model multiple laterals within any block entity.
For example. Design 1 has been completed, 6m row spacing, two laterals per row, with both laterals a nominal dripline lateral (Type 1) of 1.6lph @ 0.5m.
If an alternative ...
- Thu Jan 12, 2023 6:48 pm
- Forum: Suggestions
- Topic: Custom Graphical Blocks
- Replies: 0
- Views: 6002
Custom Graphical Blocks
Hi Irricad Team,
It would be nice to add a feature allowing users to add custom graphical maps via 'insert block' (similar to the IrricadManagement Block).
A tool where you could go into an interface similar to the management tool and assign unique descriptions to valve areas.
The ability to add ...
It would be nice to add a feature allowing users to add custom graphical maps via 'insert block' (similar to the IrricadManagement Block).
A tool where you could go into an interface similar to the management tool and assign unique descriptions to valve areas.
The ability to add ...
- Mon Dec 05, 2022 11:23 pm
- Forum: Suggestions
- Topic: Additional options for Submain and Flushing Manifold Assemblies
- Replies: 2
- Views: 7516
- Mon Dec 05, 2022 11:15 pm
- Forum: Suggestions
- Topic: Flush Sub-mains
- Replies: 7
- Views: 9301
Re: Flush Sub-mains
I agree.
Perhaps have the program assign all laterals within a 'lateral group' to the same Flushing Manifold.
I can't think of a reason where this wouldn't be case.
Perhaps have the program assign all laterals within a 'lateral group' to the same Flushing Manifold.
I can't think of a reason where this wouldn't be case.
- Tue Jul 06, 2021 11:27 am
- Forum: Suggestions
- Topic: Elevation Difference Measuring Tool
- Replies: 7
- Views: 18394
Re: Elevation Difference Measuring Tool
Thanks Dan, your right, not useful 

- Tue Jul 06, 2021 11:14 am
- Forum: Suggestions
- Topic: Elevation Difference Measuring Tool
- Replies: 7
- Views: 18394
Re: Elevation Difference Measuring Tool
Thanks Dan
I don't get a delta z only a delta x and y. Delta z is always zero and design has been interpolated.
Was there another step?
I don't get a delta z only a delta x and y. Delta z is always zero and design has been interpolated.
Was there another step?
- Mon Jul 05, 2021 6:25 pm
- Forum: Suggestions
- Topic: Elevation Difference Measuring Tool
- Replies: 7
- Views: 18394
- Tue Oct 27, 2020 7:21 pm
- Forum: Suggestions
- Topic: Additional options for Submain and Flushing Manifold Assemblies
- Replies: 2
- Views: 7516
Additional options for Submain and Flushing Manifold Assemblies
In the Irrigation block entity dialog boxes, it would be great to see
1) a drop-down option for "Submain end assemblies", with the option for more than one type of assembly should the valve not be at the end/start of the submain.
and
2) additional options available within the Flushing Manifold ...
1) a drop-down option for "Submain end assemblies", with the option for more than one type of assembly should the valve not be at the end/start of the submain.
and
2) additional options available within the Flushing Manifold ...
- Tue Oct 27, 2020 7:06 pm
- Forum: Suggestions
- Topic: Suggestions for - Tape/Spray Block Entity
- Replies: 6
- Views: 19973
Re: Suggestions for - Tape/Spray Block Entity
BUMP
I am pretty sure every Irricad user would love to have this.
From the end of the submain,
Select size 1- user to input number of metres
Select size 2- user to input number of metres
Select size 3- user to input number of metres or balance to valve
And for it to add a pipe junction between ...
- Thu Apr 16, 2020 4:36 pm
- Forum: Suggestions
- Topic: Elevation Difference Measuring Tool
- Replies: 7
- Views: 18394
Re: Elevation Difference Measuring Tool
BUMP
Friday afternoon job?
Friday afternoon job?
- Fri Jan 24, 2020 12:17 pm
- Forum: Suggestions
- Topic: Pipe Crossing Hop
- Replies: 9
- Views: 27519
Re: Pipe Crossing Hop
BUMP
BUMP
BUMP
BUMP
BUMP
BUMP
BUMP
BUMP
BUMP
- Thu Jan 02, 2020 9:56 pm
- Forum: Suggestions
- Topic: Elevations /Contours
- Replies: 3
- Views: 10371
Re: Elevations /Contours
Hi John,
For your first question, I don't think there's a way to import GE elevations onto a different layer other than Elevations. I generally move the heights from the Elevation layer to another layer before calculating the contours. Alternatively, you can leave them on the default Elevation ...
For your first question, I don't think there's a way to import GE elevations onto a different layer other than Elevations. I generally move the heights from the Elevation layer to another layer before calculating the contours. Alternatively, you can leave them on the default Elevation ...
- Fri May 17, 2019 11:29 am
- Forum: Bug Reports
- Topic: Assign Zones to system flows
- Replies: 0
- Views: 9581
Assign Zones to system flows
Hi Irricad Team,
There is a bug with the management tools, if I accidentally select "assign all zones to one system flow" when I already have a shift arrangement, it still clears management and assigns all the zones to one shift - even if I hit the cancel button. Same applies when selecting "assign ...
There is a bug with the management tools, if I accidentally select "assign all zones to one system flow" when I already have a shift arrangement, it still clears management and assigns all the zones to one shift - even if I hit the cancel button. Same applies when selecting "assign ...
- Thu May 16, 2019 12:58 pm
- Forum: Suggestions
- Topic: Zone design configuration table
- Replies: 9
- Views: 24783
Re: Zone design configuration table
Bump
If this is difficult to implement at least have the ability to leave this window open in it's current view during design / optimisation process.
Doesn't have to be live update if a 'reload' button is added.
If this is difficult to implement at least have the ability to leave this window open in it's current view during design / optimisation process.
Doesn't have to be live update if a 'reload' button is added.
- Thu May 16, 2019 12:54 pm
- Forum: Suggestions
- Topic: Suggestions for - Tape/Spray Block Entity
- Replies: 6
- Views: 19973
Re: Suggestions for - Tape/Spray Block Entity
BUMP
I am pretty sure every Irricad user would love to have this.
From the end of the submain,
Select size 1- user to input number of metres
Select size 2- user to input number of metres
Select size 3- user to input number of metres or balance to valve
And for it to add a pipe junction between ...
I am pretty sure every Irricad user would love to have this.
From the end of the submain,
Select size 1- user to input number of metres
Select size 2- user to input number of metres
Select size 3- user to input number of metres or balance to valve
And for it to add a pipe junction between ...
- Thu Oct 25, 2018 1:13 pm
- Forum: Suggestions
- Topic: Design 'Selected' Valve
- Replies: 1
- Views: 9087
Design 'Selected' Valve
Another idea that would dramatically improve efficiencies on larger designs is to be able to select a valve and choosing design selected valve > analyse (as an example).
Bonus points if you could double click on the valve and be able to adjust all the parameters found within zone design ...
Bonus points if you could double click on the valve and be able to adjust all the parameters found within zone design ...
- Tue May 08, 2018 4:34 pm
- Forum: Suggestions
- Topic: Zone design configuration table
- Replies: 9
- Views: 24783
Re: Zone design configuration table
Bump
As John Harvie notes - a key part of any design.
Would be great to have a live updating window of the zone design configuration table instead of going back and forth to it.
As John Harvie notes - a key part of any design.
Would be great to have a live updating window of the zone design configuration table instead of going back and forth to it.
- Mon Nov 27, 2017 3:29 pm
- Forum: Suggestions
- Topic: Add database information to 'Object Info'
- Replies: 0
- Views: 8591
Add database information to 'Object Info'
Hi Irricad Team,
I think it would be a great idea to include database information of a selected object and embed the detail inside the 'object info' display - probably via a new checkbox 'database info'. This is important information that should also be displayed to a designer easily and would be a ...
I think it would be a great idea to include database information of a selected object and embed the detail inside the 'object info' display - probably via a new checkbox 'database info'. This is important information that should also be displayed to a designer easily and would be a ...
- Wed Nov 08, 2017 11:43 am
- Forum: En Español
- Topic: Advertencia OOP 7
- Replies: 1
- Views: 7340
Re: Advertencia OOP 7
Hola,
Puede echar un vistazo al menú de ayuda para los mensajes de error en la sección de "referencia técnica", luego a los "error mensajes".
OOP 7: Número de punto inválido
IRRICAD ha intentado acceder a un segundo punto en un objeto de punto o un tercer punto en un objeto de línea, por ejemplo ...
Puede echar un vistazo al menú de ayuda para los mensajes de error en la sección de "referencia técnica", luego a los "error mensajes".
OOP 7: Número de punto inválido
IRRICAD ha intentado acceder a un segundo punto en un objeto de punto o un tercer punto en un objeto de línea, por ejemplo ...