Search found 7 matches

by jo
Wed Jun 19, 2024 5:32 pm
Forum: Bug Reports
Topic: IrriCAD Link V21 - Civil 3D 2023 on Windows 11
Replies: 6
Views: 5547

Re: IrriCAD Link V21 - Civil 3D 2023 on Windows 11

Hi Pancho,

Although nothing should change when upgrading to Windows 11, the newer operating system may have deleted some older system files that IRRICAD Link uses. To ensure all required system files are available re-install IRRICAD Link.

The IRRICAD Team
by jo
Wed May 29, 2024 1:25 pm
Forum: Bug Reports
Topic: Exporting to DXF file does not work...
Replies: 8
Views: 8932

Re: Exporting to DXF file does not work...

Hi Jabes,

The INPT 109 message is expected - this reminds the user that saving to DXF file will remove the 'irricad' part of pipes and outlets and only leave the geometric part of the objects. Then when opening in plain AutoCAD or BricsCAD these items will not be proxy objects and therefore will be ...
by jo
Mon Apr 15, 2024 4:28 pm
Forum: Importing and Exporting
Topic: GE import scrambled tiles
Replies: 1
Views: 2973

Re: GE import scrambled tiles

Dear Griff,

On which version of IRRICAD is this occurring? In older versions IRRICAD is not able to automatically scale when the computer text size (DPI) has been increased from 100% and you need to manually enter the "DPIScale" factor. There are several forum posts about this issue.
The newer ...
by jo
Mon Dec 18, 2023 10:25 am
Forum: Reports
Topic: Zone Summary Report with US Unit for Min Max Outlet Locations
Replies: 0
Views: 4846

Zone Summary Report with US Unit for Min Max Outlet Locations

Because of the way that the locations for the minimum and maximum outlets are determined in the reports the Minimum and Maximum Outlet location coordinates are not translated into the required US units.

To have these locations expressed in Feet please download a replacement report.
For IRRICAD ...
by jo
Mon Mar 06, 2023 1:37 pm
Forum: Reports
Topic: Export MAINLINESUM VALVE HL & RATIO to CSV
Replies: 1
Views: 3824

Re: Export MAINLINESUM VALVE HL & RATIO to CSV

Please email through your customised FPC file for us to check.
Yes, aligning the headings in the correct order can be tricky. They either need to be exact or in a slightly descending order.

The IRRICAD Team
by jo
Thu Jan 25, 2018 12:47 pm
Forum: Importing and Exporting
Topic: IRRICAD Link - Interpolate Elevations - Crash
Replies: 2
Views: 9099

Re: IRRICAD Link - Interpolate Elevations - Crash

This issue seems to be caused by a compatibility conflict with the 64-bit Surgef executable.

To fix this issue:-
1. Browse to the installed Irricad Link folder, commonly located in C:\Program Files\Irricad\Irricad Link… and locate the Surgef.exe file.
2. Right-click on Surgef.exe and select ...
by jo
Tue Jan 16, 2018 2:16 pm
Forum: Databases and Materials Selection
Topic: Labels in irribase
Replies: 2
Views: 9663

Re: Labels in irribase

Hi,

Firstly note that the label field is only used with the #Label# keyword whereas the description of an item can be placed on the design via the #DESC# keyword.

The "Label" field is located to the right of the "Supplier Cost Code" field in the Item dialog in the Database Editor.
To update many ...