Search found 8 matches

by design04
Tue Sep 23, 2025 10:40 pm
Forum: Databases and Materials Selection
Topic: Problem with Automatic Flushing Valve Fitting in Irrigation Block
Replies: 2
Views: 530

Problem with Automatic Flushing Valve Fitting in Irrigation Block

Hello everyone,

I just noticed that it is now possible to automatically add a flushing valve when creating an irrigation block. After testing, I found an issue.
Screenshot 2025-09-23 173803.png
If the zone pipe size does not match the flushing valve size, the fitting is displayed incorrectly. For ...
by design04
Fri Sep 19, 2025 9:15 pm
Forum: Databases and Materials Selection
Topic: Issue with Automatic Display of PVC Fitting in Database
Replies: 7
Views: 906

Re: Issue with Automatic Display of PVC Fitting in Database

From my testing, if I add “Tee Reducers” to both the “Tees” component group and the “Lateral takeoffs” component group, the display works correctly.

As shown in the picture from my previous post, “Tee Reducers” and “Reducers” are grouped together. However, if I don’t include “Tee Reducers” in the ...
by design04
Fri Sep 19, 2025 3:56 pm
Forum: Databases and Materials Selection
Topic: Issue with Automatic Display of PVC Fitting in Database
Replies: 7
Views: 906

Re: Issue with Automatic Display of PVC Fitting in Database

I have sent the requested design and database files to your support email.

Thank you for your assistance.
by design04
Fri Sep 19, 2025 3:11 pm
Forum: Databases and Materials Selection
Topic: Issue with Automatic Display of PVC Fitting in Database
Replies: 7
Views: 906

Re: Issue with Automatic Display of PVC Fitting in Database

I used Option B and it worked. However, I’ve encountered the same issue with fittings that are PVC to LDPE sized 2" and above. For fittings sized 2" and below, this problem does not occur.

Screenshot 2025-09-19 100804.png
From the picture, the expected result should be a PVC Saddle Clamp 5"x3/4 ...
by design04
Thu Sep 18, 2025 9:05 pm
Forum: Databases and Materials Selection
Topic: Issue with Automatic Display of PVC Fitting in Database
Replies: 7
Views: 906

Issue with Automatic Display of PVC Fitting in Database

Hello everyone,

I’m having an issue with the automatic display of the PVC 5" fitting.
The expected result should be a PVC Tee Reducer 5"x1", but as shown in the picture ,it is displayed as a PVC Tee Reducer 4"x1" instead.
Screenshot 2025-09-18 155842.png

This problem does not occur with fittings ...
by design04
Wed Jul 23, 2025 2:25 pm
Forum: Importing and Exporting
Topic: Export to DWG
Replies: 2
Views: 1412

Re: Export to DWG

It worked. Thank you.
by design04
Mon Jul 21, 2025 8:38 pm
Forum: Importing and Exporting
Topic: Export to DWG
Replies: 2
Views: 1412

Export to DWG

Hello everyone,
I’m a beginner user of Irricad.
I have a problem when exporting files to DWG format.
In the exported file, the text size is bigger than it appears in the Irricad program.
I want the exported text to keep the same size as in Irricad.
Please help me with this.

Thank you!