Search found 4 matches

by luiskuonqui
Sat Sep 17, 2011 2:44 am
Forum: Hydraulic Design
Topic: Zone/lateral pipe design
Replies: 6
Views: 14733

Re: Zone/lateral pipe design

Many thanks!

You have improved a lot my knowledge about IRRICAD and my strength to design.

LK
by luiskuonqui
Fri Sep 16, 2011 2:49 am
Forum: Hydraulic Design
Topic: Zone/lateral pipe design
Replies: 6
Views: 14733

Re: Zone/lateral pipe design

Awesome clearly, thanks!

If I wish to use laterals with more than one diameter I HAVE to use "Unconnected", it is impossible to use "Unconnected" and IRRICAD to only use "L", ain´t it? and, if I use "Connected" it is not allowed to bring more than one diameter per lateral, am i right?

Thanks!
by luiskuonqui
Sun Sep 11, 2011 12:45 am
Forum: Hydraulic Design
Topic: Zone/lateral pipe design
Replies: 6
Views: 14733

Zone/lateral pipe design

Hi,

I have a problem designing zones and don't know how to solve that, I will try to explain it.

I will use an example, I usually design Zone pipes in diameters 110-50 and in data base y mark these as Z, and Lateral in 32-20 these with L, when i "LP Design" zones the software only takes 110-50 for ...
by luiskuonqui
Fri Jul 22, 2011 5:37 am
Forum: Bug Reports
Topic: Not showing spray symbols
Replies: 1
Views: 7733

Not showing spray symbols

When I draw Spray Blocks or Spryline Blocks, the symbols of any Spray are not showing but the "Extra Outlet on Ends".

I mean, I can see the symbol and wetted radius of the extra outlets near the edges, but I can't see the main outlets, but if I open desings finished before the issue started I see ...