- Wed Jan 08, 2025 10:38 am
- Forum: Miscellaneous
- Topic: configure label
- Replies: 1
- Views: 61
Re: configure label
Good evening. I suggest to check the following options in Settings|Labels :- - if the "Check label length" option is enabled. Uncheck this setting. It is likely that the label is longer than the pipe / combined pipes and therefore won't be created. - the "Angle tolerance" field. ...
- Mon Dec 16, 2024 5:07 pm
- Forum: Reports
- Topic: Number of Lines per Irrigation Block in Zone Design Report
- Replies: 3
- Views: 800
Re: Number of Lines per Irrigation Block in Zone Design Report
It appears that I was incorrect and we can't really do this successfully in the current reports as it will only work for a limited set of circumstances. However, if you have a submain on one end and only only sized lateral in the connected spraylines the report can successfully add up the number of ...
- Thu Dec 12, 2024 3:02 pm
- Forum: Bug Reports
- Topic: Database exemption error (3022)
- Replies: 1
- Views: 142
Re: Database exemption error (3022)
This message appears when the design's internal symbol table is corrupted or if the symbol table in your customised database is significantly different from the Skeleton.mdb file, which is used to create each design's internal database. Although annoying, the messages don't affect anything and can b...
- Wed Dec 11, 2024 12:36 pm
- Forum: Miscellaneous
- Topic: Issues Launching Irricad Link
- Replies: 4
- Views: 222
Re: Issues Launching Irricad Link
Hi James, I was thinking that the issue might be the default template you are using in IRRICAD Link, however with your edit now saying BricsCAD won't load with the Irricad64.brx APPLOADed that doesn't seem likely. To fix your plain BricsCAD try starting it in safemode so that you can unload the Irri...
- Wed Dec 11, 2024 8:55 am
- Forum: Miscellaneous
- Topic: Issues Launching Irricad Link
- Replies: 4
- Views: 222
Re: Issues Launching Irricad Link
There is another check you can do in BricsCAD to check if it is hanging when loading the Irricad64.brx file. 1. Open plain BricsCAD. 2. In Settings|Settings (or CONFIG on the command line) open Program Options|Files 3. In the "Support file search path" add the location of your Irricad fold...
- Wed Dec 11, 2024 8:26 am
- Forum: Miscellaneous
- Topic: Issues Launching Irricad Link
- Replies: 4
- Views: 222
Re: Issues Launching Irricad Link
This could be a dongle issue. Are you able to run Standalone on your computer or try your dongle on another computer that has IRRICAD? The other issue could be that you no longer require the other V20 brx type that was previously used on your computer. (Note this issue has been overcome in Version 2...
- Tue Dec 10, 2024 12:35 pm
- Forum: Importing and Exporting
- Topic: link import from KML not working
- Replies: 5
- Views: 322
Re: link import from KML not working
Thank you for letting us know.
We do not have a standard menu option for the IRR_FILEGEIMPORTKML command.
Someone has added it to your menu and used the command for Import Data.
The IRRICAD Team
We do not have a standard menu option for the IRR_FILEGEIMPORTKML command.
Someone has added it to your menu and used the command for Import Data.
The IRRICAD Team
- Mon Dec 09, 2024 3:21 pm
- Forum: Importing and Exporting
- Topic: link import from KML not working
- Replies: 5
- Views: 322
Re: link import from KML not working
Hi Ari, 1) Are you able to successfully use Import from Google Earth ? 2) Try and access the functionality outside of BricsCAD. To do this:- a) Run a command prompt (CMD) b) Browse to your IRRICAD Link folder by changing the directory, e.g., cd C:\ cd program files cd irricad cd irricad link for bri...
- Fri Dec 06, 2024 1:47 pm
- Forum: Importing and Exporting
- Topic: link import from KML not working
- Replies: 5
- Views: 322
Re: link import from KML not working
Hi Ari, It does sound like the cause is the issue you tried to fix with Dan's post. Please check that the version of your IrricadGEImport.exe is 1.0.8796.17033. You can do this by browsing to your installed IRRICAD Link folder, commonly located in C:\Program Files\Irricad\Irricad Link BricsCAD, and ...
- Tue Nov 19, 2024 1:38 pm
- Forum: En Español
- Topic: Error en Base de Datos
- Replies: 2
- Views: 191
Re: Error en Base de Datos
El problema se debía a una cinta dañada que no tenía ningún parámetro. Eliminar el elemento de la base de datos solucionó el problema. En este caso, el elemento era "invisible" en el grupo de componentes Cinta y era necesario eliminarlo mediante la opción "Consulta". Tenga en cue...
- Tue Nov 19, 2024 1:25 pm
- Forum: Bug Reports
- Topic: Pipe lengths not rounding if in assembly
- Replies: 1
- Views: 216
Re: Pipe lengths not rounding if in assembly
Thank you for letting us know about this. It will be fixed in the next Link patch (no release date for this as yet).
The IRRICAD Team
The IRRICAD Team
- Wed Nov 13, 2024 10:59 am
- Forum: Bug Reports
- Topic: IrriCAD Link V21 - Civil 3D 2023 fatal error
- Replies: 3
- Views: 337
Re: IrriCAD Link V21 - Civil 3D 2023 fatal error
Unfortunately, it does appear that Link Version 21.XX.33 has an issue with trimming unconnected spraylines when using the Irrigation Spray Block options, causing a crash in AutoCAD and leaving open transactions in BricsCAD. Until this is fixed the method to use is the Trim Spraylines tool available ...
- Wed Nov 13, 2024 7:56 am
- Forum: Bug Reports
- Topic: IrriCAD Link V21 - Civil 3D 2023 fatal error
- Replies: 3
- Views: 337
Re: IrriCAD Link V21 - Civil 3D 2023 fatal error
Hi Pancho,
Do you mean that the design has a fatal error upon opening or when you are trying to edit the design in 21.23.33?
It sounds like you will need to send your design for us to have a look at. You can send this to your local support team or to us at Support@IRRICAD.com.
The IRRICAD Team
Do you mean that the design has a fatal error upon opening or when you are trying to edit the design in 21.23.33?
It sounds like you will need to send your design for us to have a look at. You can send this to your local support team or to us at Support@IRRICAD.com.
The IRRICAD Team
- Fri Oct 18, 2024 12:14 pm
- Forum: Suggestions
- Topic: Wish - System flows dialog to match Area Colors
- Replies: 4
- Views: 307
Re: Wish - System flows dialog to match Area Colors
You are able to place the management symbol on the screen / model by:- - in IRRICAD Standalone – after graphical management go to Draw|Management Symbol . - In IRRICAD Link - after graphical management go to Insert|Insert Block. In the dropdown list look for the “IrricadManagement” block. The IRRICA...
- Thu Oct 17, 2024 4:04 pm
- Forum: Suggestions
- Topic: Wish - System flows dialog to match Area Colors
- Replies: 4
- Views: 307
Re: Wish - System flows dialog to match Area Colors
Thank you for the suggestion, I have added it to our requested features list. Note that in some situations a zone is in multiple system flows and this won’t be able to be indicted in the floating dialog, as the hatching will be a combination of the colours. For your side question I’m not exactly sur...
- Wed Oct 16, 2024 4:29 pm
- Forum: Announcements
- Topic: New Patch for IRRICAD Link Version 21
- Replies: 0
- Views: 611
New Patch for IRRICAD Link Version 21
The new Patch for IRRICAD Link V21 is now available - v21.XX.33 This patch contains a few additions and bug fixes:- - the Pivot Module (see our forum post “IRRICAD Releases the Pivot Module for IRRICAD Link V21” (https://www.irricad.com/phpbb3/viewtopic.php?p=2661#p2661) for more information) - impr...
- Wed Oct 16, 2024 4:18 pm
- Forum: Announcements
- Topic: IRRICAD Releases the Pivot Module for IRRICAD Link V21
- Replies: 0
- Views: 580
IRRICAD Releases the Pivot Module for IRRICAD Link V21
The eagerly awaited Pivot Module for IRRICAD Link is now available! Included in the latest patch V21.xx.33, along with other improvements and bug fixes, the Pivot Module is enabled for IRRICAD Link V21 users to trial until 15th December 2024 . To continue using the module after this date please cont...
- Tue Oct 08, 2024 1:27 pm
- Forum: CAD Drawing
- Topic: Mainline Cut Pipe not working properly...
- Replies: 3
- Views: 281
Re: Mainline Cut Pipe not working properly...
We are sorry to hear that you are having an issue with the Mainline Cut Pipe tool in IRRICAD Link. Can you please check the following:- - the items you are trying to connect with the Mainline Cut Pipe tool are definitely mainline pipes or spraylines - the IRR_MAINLINE_JUNCTIONS layer is not frozen -...
- Tue Oct 08, 2024 10:20 am
- Forum: Suggestions
- Topic: Show zone elevation map
- Replies: 1
- Views: 186
Re: Show zone elevation map
Thank you for the suggestion. I will add this to our list of requested Features.
The IRRICAD Team
The IRRICAD Team
- Fri Sep 20, 2024 4:53 pm
- Forum: Hydraulic Design
- Topic: travel time
- Replies: 1
- Views: 188
Re: travel time
The “Maximum Lateral Travel Time” noted in the Zone Summary report is the travel time just for the longest lateral in the zone, from the start of the lateral to the end of the lateral. You will also see this value in the Zone Travel Time Report “Lateral” column when you locate the longest lateral. T...