Search found 863 matches

by jovivier
Fri Jun 14, 2024 11:59 am
Forum: Suggestions
Topic: Math functions for more Label fields
Replies: 3
Views: 76

Re: Math functions for more Label fields

Hi Nick, The rounding works with most keywords, is there one you have found where is doesn't work? You can have any rounding that you want, e.g., 0.00001. It appears to work for me ACTFLOW. What additional specific math are you requiring? The current math format should work with all keywords:- #<key...
by jovivier
Mon Jun 10, 2024 4:16 pm
Forum: Miscellaneous
Topic: Labels
Replies: 1
Views: 160

Re: Labels

The Minimum and maximum labels settings are located in Report|Report Settings . Click the [Text] button to configure the text height. Note that Version 21 has new default layers, including one for labels and one for screen reporting, however if you had previously added your own permanent layers (tha...
by jovivier
Fri May 31, 2024 11:14 am
Forum: Reports
Topic: Where is ReportEditor.exe?
Replies: 1
Views: 195

Re: Where is ReportEditor.exe?

Hi Nick, Currently there is no Report Editor available with the IRRICAD Link version. In IRRICAD Standalone the ReportEditor.exe is located in the installed IRRUCAD folder, commonly C:\Program Files (x86)\Irricad\Irricad Pro XX. Please note that most people will find it difficult to use and there is...
by jovivier
Thu May 30, 2024 4:37 pm
Forum: Suggestions
Topic: Simulate Multiple lateral functions
Replies: 2
Views: 2650

Re: Simulate Multiple lateral functions

Thank you for your suggestions. We will consider them however it is likely to be awkward to do. When multiple laterals are using the same riser you may find our “How To” forum post useful for fitting selection useful - “How To Correct Fitting Selection For Dual-Line Systems” (https://www.irricad.com...
by jovivier
Thu May 30, 2024 1:51 pm
Forum: Suggestions
Topic: Wish - Bulk edit Database items
Replies: 1
Views: 241

Re: Wish - Bulk edit Database items

Hi Nick,

You can already bulk edit the database. See our Tips forum post "47. CHANGING DATABASE ITEM USAGES QUICKLY" (viewtopic.php?p=770#p770) for assistance.

Does this help meet your requirements?

The IRRICAD Team
by jovivier
Wed Apr 24, 2024 2:11 pm
Forum: Databases and Materials Selection
Topic: Addressing Nominal Pressure Alarm in Air Valves PN10 & PN16
Replies: 3
Views: 976

Re: Addressing Nominal Pressure Alarm in Air Valves PN10 & PN16

We have created two replacement reports will that will suppress the "Over Pressure" markers for any Misc. Hydraulic items in the Mainline Pipe Node and Node Name reports. 1. Download PipeNodeReportsRepressedMHmarkers.zip 2. Save the zip file to a location of your choice. 3. Browse to the l...
by jovivier
Wed Apr 17, 2024 12:30 pm
Forum: Bug Reports
Topic: IrriCAD Link V21 - Civil 3D 2023 CUIX problem...
Replies: 2
Views: 434

Re: IrriCAD Link V21 - Civil 3D 2023 CUIX problem...

We're sorry to hear that you are having an issue. Does IRRICAD Link run inside C3D 2023? The messages do not look like they are to do with IRRICAD but with the C3D installation itself. Does your default C3D work as expected or does it also have the same issues and supply the same messages? Here are ...
by jovivier
Tue Mar 26, 2024 12:40 pm
Forum: CAD Drawing
Topic: How to Indicate Flow Direction on Laterals/Spray Lines
Replies: 1
Views: 437

Re: How to Indicate Flow Direction on Laterals/Spray Lines

Hi Sergio, For automatic options, currently the "Flow Direction” label only works for Mainline Pipes due to the system flow number needing to be specified as part of the label requirements. We are looking at extending this to include Zone items in the future. There is also the "Pipe Reduct...
by jovivier
Thu Mar 21, 2024 4:11 pm
Forum: Miscellaneous
Topic: Copying from Object Info in V21.28 into Excel
Replies: 0
Views: 365

Copying from Object Info in V21.28 into Excel

In V21.28 we made some changes to ensure that the hydraulic information tables always line up correctly, even with tabular data such as the Pivot output and other languages. This meant changing the font and moving from tab-delimited to space-delimited format. However, when you paste directly from th...
by jovivier
Thu Mar 21, 2024 3:51 pm
Forum: Databases and Materials Selection
Topic: Addressing Nominal Pressure Alarm in Air Valves PN10 & PN16
Replies: 3
Views: 976

Re: Addressing Nominal Pressure Alarm in Air Valves PN10 & PN16

Hi Sergio, Thank you for the required information, that is the red asterixis in the Pipe and Pipe Node reports that you are referring to. As Misc. Hydraulic items do not have a maximum allowable pressure field in the database therefore this is zero "Allowable Pressure" column in the Pipe a...
by jovivier
Mon Mar 18, 2024 12:17 pm
Forum: Support FAQs
Topic: If Standalone Database Editor Gives "Data source name not found and no default driver specified" message
Replies: 0
Views: 428

If Standalone Database Editor Gives "Data source name not found and no default driver specified" message

If your IRRICAD Standalone Database Editor gives a "Data source name not found and no default driver specified" message but IRRICAD itself does not then the MS Access 32bit driver has somehow been removed. To fix please follow the below steps:- 1. Browse to your installed IRRICAD \Database...
by jovivier
Wed Mar 13, 2024 10:14 am
Forum: Announcements
Topic: IRRICAD Releases the Pivot Module for IRRICAD Standalone V21
Replies: 1
Views: 2167

Re: IRRICAD Releases the Pivot Module for IRRICAD Standalone V21

For full help for the module see Help|Release Notes – Pivot Module in V21.28 or download the latest Standalone Release Notes chm file from https://www.irricad.com/manuals-guides/.

The IRRICAD Team
by jovivier
Tue Feb 27, 2024 12:24 pm
Forum: Announcements
Topic: IRRICAD Releases the Pivot Module for IRRICAD Standalone V21
Replies: 1
Views: 2167

IRRICAD Releases the Pivot Module for IRRICAD Standalone V21

Pivot Module This companion product has been developed to include the theoretical design and analysis of center pivots. This module is currently available as an add-on to IRRICAD Standalone Version 21. (We hope to release a Pivot module for IRRICAD Link V21 mid-2024). - Create full or part circle c...
by jovivier
Mon Feb 26, 2024 4:02 pm
Forum: Hydraulic Design
Topic: Define max main pipe head loss
Replies: 1
Views: 503

Re: Define max main pipe head loss

Thank you for your question. Mainline LP Design trades running costs (cost of power) against the cost of capital plus interest to find the most economic pipe selection for the system that will meet the control valve or mainline outlet pressure requirements. You can turn off the "Trade capital c...
by jovivier
Mon Feb 26, 2024 1:12 pm
Forum: FAQs for IRRICAD Link
Topic: If Irricad64.brx / arx File Only Loads Intermittently Under Windows 11
Replies: 0
Views: 503

If Irricad64.brx / arx File Only Loads Intermittently Under Windows 11

If IRRICAD Link V21 loads intermittently, even after restarting the computer, when running Windows 11 then you may need a newer sentinel driver. Of course, first check that the dongle is securely plugged in or try a different port. Note that the symptoms seen in BricsCAD will be:- - the IRRICAD Link...
by jovivier
Fri Feb 23, 2024 1:31 pm
Forum: En Español
Topic: Crear leyenda
Replies: 1
Views: 370

Re: Crear leyenda

Las leyendas se pueden agregar a través de la herramienta Crear Leyenda del menú Plantilla Ploteo . Para crear una leyenda, necesita un rectángulo, una línea o símbolo como marcador de posición para la tubería o salida/válvula, un fragmento de texto para indicar la fuente y el tamaño, y un relleno. ...
by jovivier
Wed Feb 21, 2024 4:14 pm
Forum: En Español
Topic: Crear plantilla ploteo
Replies: 1
Views: 388

Re: Crear plantilla ploteo

Querida Lourdes, Gracias por su pregunta. Hay información en Ayuda|Temas de Ayuda - User Manual -> Advanced Topics -> Editing Plot Templates que debería ayudarle. Además, también hay un tutorial paso a paso (Tutorials -> Plot Templates -> Edit an Existing Plot Template) para ayudarle a crear una pla...
by jovivier
Wed Feb 21, 2024 3:45 pm
Forum: Databases and Materials Selection
Topic: Addressing Nominal Pressure Alarm in Air Valves PN10 & PN16
Replies: 3
Views: 976

Re: Addressing Nominal Pressure Alarm in Air Valves PN10 & PN16

Hi Sergio, Unfortunately, we are not sure what you mean? Misc. Hydraulic items do not have pressure or pressure rating fields or warning messages. The only messages given would be above or below the flow limits or for PRVs when there is not enough upstream pressure. If you would like to send us an e...
by jovivier
Wed Feb 14, 2024 3:51 pm
Forum: Reports
Topic: Obtaining Plant Count and Area Report in Irricad
Replies: 2
Views: 719

Re: Obtaining Plant Count and Area Report in Irricad

There is actually a way to obtain a CSV report for the symbol count. The 'Symbol Count' function is a VCADD tool that is not utilised in IRRICAD therefore a script will need to be added. This is achieved via the CmdExt.vcdef file, located in your installed IRRICAD folder. Follow the process below:-...
by jovivier
Tue Feb 13, 2024 3:52 pm
Forum: Reports
Topic: Obtaining Plant Count and Area Report in Irricad
Replies: 2
Views: 719

Re: Obtaining Plant Count and Area Report in Irricad

Hi Sergio, In IRRICAD you are able to select items and obtain a "Count" count via the Info Panel, on the bottom right of the status bar. Unfortunately it isn't possible to obtain a report, such as a BOM, for non-hydraulic items. However, one method could be to make a copy of your design an...