Search found 882 matches
- Thu Sep 12, 2024 1:59 pm
- Forum: Hydraulic Design
- Topic: Filling a Reservoir
- Replies: 3
- Views: 71
Re: Filling a Reservoir
The water supply pressure is being calculated on providing the required pressure at the outlet, and not the highest elevation along the way. However with the permanent junctions along the pipeline IRRICAD tell you the pressure (positive or negative) at these points. Also note that in your example th...
- Mon Sep 09, 2024 11:40 am
- Forum: Importing and Exporting
- Topic: Missing elevations
- Replies: 3
- Views: 201
Re: Missing elevations
It appears that Google has now fixed this issue.
The IRRICAD Team
The IRRICAD Team
- Fri Sep 06, 2024 9:08 am
- Forum: Importing and Exporting
- Topic: Missing elevations
- Replies: 3
- Views: 201
Re: Missing elevations
Unfortunately Google recently made some changes and this introduced a bug. What happens is that some data is corrupted so the download is stopped and Google issues the DATA_NOT_AVAILABLE message, which causes our software to issue the 'Quota exceeded' message. The good news is that this only happens...
- Thu Sep 05, 2024 9:14 am
- Forum: Databases and Materials Selection
- Topic: computer selection fittings
- Replies: 4
- Views: 474
Re: computer selection fittings
Hi Nathan,
It sounds like your 75mm coupler may have the incorrect fitting code or gender. You are welcome to send us your database to look at. Email Support@IRRICAD.com . Note that you may need to zip up your database to send it through email.
The IRRICAD Team
It sounds like your 75mm coupler may have the incorrect fitting code or gender. You are welcome to send us your database to look at. Email Support@IRRICAD.com . Note that you may need to zip up your database to send it through email.
The IRRICAD Team
- Wed Sep 04, 2024 1:34 pm
- Forum: Reports
- Topic: Number of Lines per Irrigation Block in Zone Design Report
- Replies: 1
- Views: 477
Re: Number of Lines per Irrigation Block in Zone Design Report
Firstly, note that the NUMLAT and NUMROW label keywords may be applied to Irrigation Blocks and not to control valves (i.e. zones). In many cases, but not always, the zone is a single block and therefore these keywords will give the numbers for the zone as a whole. Note also that NUMLAT will display...
- Tue Sep 03, 2024 11:54 am
- Forum: Databases and Materials Selection
- Topic: computer selection fittings
- Replies: 4
- Views: 474
Re: computer selection fittings
Please note the updated reply above.
The IRRICAD Team
The IRRICAD Team
- Mon Sep 02, 2024 6:04 pm
- Forum: Databases and Materials Selection
- Topic: computer selection fittings
- Replies: 4
- Views: 474
Re: computer selection fittings
Hello, Without seeing your design and database we can only comment in general. The first tip is to make sure that your Coupler component group contains pieces of plain PVC pipe. In the master IRRICAD database these are called "PVC plain male coupler" with all sizes. (You can use Edit|Copy ...
- Wed Aug 28, 2024 9:58 am
- Forum: Hydraulic Design
- Topic: missing Hydraulic information from someone else irricad
- Replies: 2
- Views: 497
Re: missing Hydraulic information from someone else irricad
Please note that V21.31 can open designs created in V21.11 however V21.11 cannot successfully open designs created in V21.28 or later, due to the addition of the Pivot Module. We recommend upgrading all of your IRRICADs to the latest V21 release, either via Help|Check for Updates or by going to http...
- Tue Aug 13, 2024 4:42 pm
- Forum: How To
- Topic: How to Send a Crash Report Manually When SMTP is Disabled
- Replies: 0
- Views: 521
How to Send a Crash Report Manually When SMTP is Disabled
When an issue occurs in IRRICAD which shuts down the program it is important to send us the session and error logs, along with a copy of the design (if you are happy to do so), and a detailed description of what you were doing when it crashed so that we can find the cause of the problem. The automat...
- Mon Aug 12, 2024 4:58 pm
- Forum: Announcements
- Topic: A new patch is now available for Standalone V21 (21.30).
- Replies: 1
- Views: 950
Re: A new patch is now available for Standalone V21 (21.30).
Please note that we have resolved an issue where the patching over 21.29 did not work correctly and we have now replaced v21.30 with v21.31. The instructions above will supply you with this latest patch.
We apologise for any inconvenience.
The IRRICAD Team
We apologise for any inconvenience.
The IRRICAD Team
- Mon Aug 12, 2024 4:54 pm
- Forum: Announcements
- Topic: IMPORTANT Announcement About V21.30 Patch
- Replies: 0
- Views: 561
IMPORTANT Announcement About V21.30 Patch
We have discovered a problem when patching V21.29 with v21.30, where some DLL files were not updated. This caused issues with Zone Design Configuration , the tabular management options, and editing geometric objects. We apologise for this. A new patch, v21.31, has been released to resolve the proble...
- Thu Aug 08, 2024 2:49 pm
- Forum: Announcements
- Topic: A new patch is now available for Standalone V21 (21.30).
- Replies: 1
- Views: 950
A new patch is now available for Standalone V21 (21.30).
A new patch is now available for Standalone V21 (21.30). This patch contains a few additions and bug fixes. See https://www.irricad.com/irricad/download/upgrade/ProV10/Readme.txt. Most notably, the issue affecting Spray Blocks in V21.29 has been fixed, the DAZ export has been upgraded to export Pivo...
- Fri Aug 02, 2024 11:11 am
- Forum: Importing and Exporting
- Topic: Opening Earlier Versions
- Replies: 3
- Views: 854
Re: Opening Earlier Versions
Hi David,
It does sound like the internal database may be corrupted.
Alternatively, you can import the vcd file and, if you know the products, can convert geometric objects into the required hydraulic items.
The IRRICAD Team
It does sound like the internal database may be corrupted.
Alternatively, you can import the vcd file and, if you know the products, can convert geometric objects into the required hydraulic items.
The IRRICAD Team
- Tue Jul 30, 2024 4:05 pm
- Forum: Importing and Exporting
- Topic: Opening Earlier Versions
- Replies: 3
- Views: 854
Re: Opening Earlier Versions
Hi David, Opening V8 designs in newer versions appears to be working well. Please note that any designs pre- V13 will not have the internal files zipped in to the .DEZ format. The minimum required for a design in older versions was the .DES file, the .VCD file, and the .MDB file for the same file na...
- Fri Jul 12, 2024 4:26 pm
- Forum: Databases and Materials Selection
- Topic: SQL database queries
- Replies: 1
- Views: 906
Re: SQL database queries
Hi Guilhermeantoinio, The database editor manual is a good place to start learning about how the database editor works. Unfortunately we do not teach SQL but are happy to write specific queries upon request for current version users. There are also quite a few forum posts about the database editor a...
- Fri Jun 21, 2024 11:27 am
- Forum: Announcements
- Topic: New Patch for IRRICAD Standalone Version 21
- Replies: 0
- Views: 1404
New Patch for IRRICAD Standalone Version 21
A new patch is now available for Standalone V21 (21.29). This patch contains a few additions and bug fixes. See https://www.irricad.com/irricad/download/upgrade/ProV10/Readme.txt for more information. Most notably, the number of water supplies has been increased to 50, and few minor bug fixes in the...
- Thu Jun 20, 2024 5:23 pm
- Forum: Announcements
- Topic: IRRICAD Releases the Pivot Module for IRRICAD Standalone V21
- Replies: 2
- Views: 3724
Re: IRRICAD Releases the Pivot Module for IRRICAD Standalone V21
A Pivot Demonstration video is now available on our YouTube channel. Watch from https://youtu.be/OHJxmBHZ9ho or our Videos page https://www.irricad.com/videos/
The IRRICAD Team
The IRRICAD Team
- Thu Jun 20, 2024 9:20 am
- Forum: Bug Reports
- Topic: IrriCAD Link V21 - Civil 3D 2023 on Windows 11
- Replies: 6
- Views: 1946
Re: IrriCAD Link V21 - Civil 3D 2023 on Windows 11
To re-install IRRICAD Link correctly, un-install IRRICAD Link and remove the IRRICAD Profile from the registry in Computer\HKEY_CURRENT_USER\SOFTWARE\Autodesk - look for C3D and under the "Profile" key highlight and remove the "Irricad" profile. 1. Ensure your user login has admi...
- Thu Jun 20, 2024 8:53 am
- Forum: Bug Reports
- Topic: IrriCAD Link V21 - Civil 3D 2023 on Windows 11
- Replies: 6
- Views: 1946
Re: IrriCAD Link V21 - Civil 3D 2023 on Windows 11
Hi Pancho, Did you check through the steps as per the forum post "How to run IRRICAD Link inside AutoCAD Civil 3D" (https://www.irricad.com/phpbb3/viewtopic.php?p=1367#p1367) to make sure all the settings were still set? I would try this before re-installing C3D. No, IRRICAD Link V21 will ...
- Fri Jun 14, 2024 11:59 am
- Forum: Suggestions
- Topic: Math functions for more Label fields
- Replies: 5
- Views: 1863
Re: Math functions for more Label fields
Hi Nick, The rounding works with most keywords, is there one you have found where is doesn't work? You can have any rounding that you want, e.g., 0.00001. It appears to work for me ACTFLOW. What additional specific math are you requiring? The current math format should work with all keywords:- #<key...