Search found 858 matches

by jovivier
Wed Apr 24, 2024 2:11 pm
Forum: Databases and Materials Selection
Topic: Addressing Nominal Pressure Alarm in Air Valves PN10 & PN16
Replies: 3
Views: 657

Re: Addressing Nominal Pressure Alarm in Air Valves PN10 & PN16

We have created two replacement reports will that will suppress the "Over Pressure" markers for any Misc. Hydraulic items in the Mainline Pipe Node and Node Name reports. 1. Download PipeNodeReportsRepressedMHmarkers.zip 2. Save the zip file to a location of your choice. 3. Browse to the l...
by jovivier
Wed Apr 17, 2024 12:30 pm
Forum: Bug Reports
Topic: IrriCAD Link V21 - Civil 3D 2023 CUIX problem...
Replies: 2
Views: 216

Re: IrriCAD Link V21 - Civil 3D 2023 CUIX problem...

We're sorry to hear that you are having an issue. Does IRRICAD Link run inside C3D 2023? The messages do not look like they are to do with IRRICAD but with the C3D installation itself. Does your default C3D work as expected or does it also have the same issues and supply the same messages? Here are ...
by jovivier
Tue Mar 26, 2024 12:40 pm
Forum: CAD Drawing
Topic: How to Indicate Flow Direction on Laterals/Spray Lines
Replies: 1
Views: 220

Re: How to Indicate Flow Direction on Laterals/Spray Lines

Hi Sergio, For automatic options, currently the "Flow Direction” label only works for Mainline Pipes due to the system flow number needing to be specified as part of the label requirements. We are looking at extending this to include Zone items in the future. There is also the "Pipe Reduct...
by jovivier
Thu Mar 21, 2024 4:11 pm
Forum: Miscellaneous
Topic: Copying from Object Info in V21.28 into Excel
Replies: 0
Views: 190

Copying from Object Info in V21.28 into Excel

In V21.28 we made some changes to ensure that the hydraulic information tables always line up correctly, even with tabular data such as the Pivot output and other languages. This meant changing the font and moving from tab-delimited to space-delimited format. However, when you paste directly from th...
by jovivier
Thu Mar 21, 2024 3:51 pm
Forum: Databases and Materials Selection
Topic: Addressing Nominal Pressure Alarm in Air Valves PN10 & PN16
Replies: 3
Views: 657

Re: Addressing Nominal Pressure Alarm in Air Valves PN10 & PN16

Hi Sergio, Thank you for the required information, that is the red asterixis in the Pipe and Pipe Node reports that you are referring to. As Misc. Hydraulic items do not have a maximum allowable pressure field in the database therefore this is zero "Allowable Pressure" column in the Pipe a...
by jovivier
Mon Mar 18, 2024 12:17 pm
Forum: Support FAQs
Topic: If Standalone Database Editor Gives "Data source name not found and no default driver specified" message
Replies: 0
Views: 245

If Standalone Database Editor Gives "Data source name not found and no default driver specified" message

If your IRRICAD Standalone Database Editor gives a "Data source name not found and no default driver specified" message but IRRICAD itself does not then the MS Access 32bit driver has somehow been removed. To fix please follow the below steps:- 1. Browse to your installed IRRICAD \Database...
by jovivier
Wed Mar 13, 2024 10:14 am
Forum: Announcements
Topic: IRRICAD Releases the Pivot Module for IRRICAD Standalone V21
Replies: 1
Views: 1736

Re: IRRICAD Releases the Pivot Module for IRRICAD Standalone V21

For full help for the module see Help|Release Notes – Pivot Module in V21.28 or download the latest Standalone Release Notes chm file from https://www.irricad.com/manuals-guides/.

The IRRICAD Team
by jovivier
Tue Feb 27, 2024 12:24 pm
Forum: Announcements
Topic: IRRICAD Releases the Pivot Module for IRRICAD Standalone V21
Replies: 1
Views: 1736

IRRICAD Releases the Pivot Module for IRRICAD Standalone V21

Pivot Module This companion product has been developed to include the theoretical design and analysis of center pivots. This module is currently available as an add-on to IRRICAD Standalone Version 21. (We hope to release a Pivot module for IRRICAD Link V21 mid-2024). - Create full or part circle c...
by jovivier
Mon Feb 26, 2024 4:02 pm
Forum: Hydraulic Design
Topic: Define max main pipe head loss
Replies: 1
Views: 322

Re: Define max main pipe head loss

Thank you for your question. Mainline LP Design trades running costs (cost of power) against the cost of capital plus interest to find the most economic pipe selection for the system that will meet the control valve or mainline outlet pressure requirements. You can turn off the "Trade capital c...
by jovivier
Mon Feb 26, 2024 1:12 pm
Forum: FAQs for IRRICAD Link
Topic: If Irricad64.brx / arx File Only Loads Intermittently Under Windows 11
Replies: 0
Views: 323

If Irricad64.brx / arx File Only Loads Intermittently Under Windows 11

If IRRICAD Link V21 loads intermittently, even after restarting the computer, when running Windows 11 then you may need a newer sentinel driver. Of course, first check that the dongle is securely plugged in or try a different port. Note that the symptoms seen in BricsCAD will be:- - the IRRICAD Link...
by jovivier
Fri Feb 23, 2024 1:31 pm
Forum: En Español
Topic: Crear leyenda
Replies: 1
Views: 232

Re: Crear leyenda

Las leyendas se pueden agregar a través de la herramienta Crear Leyenda del menú Plantilla Ploteo . Para crear una leyenda, necesita un rectángulo, una línea o símbolo como marcador de posición para la tubería o salida/válvula, un fragmento de texto para indicar la fuente y el tamaño, y un relleno. ...
by jovivier
Wed Feb 21, 2024 4:14 pm
Forum: En Español
Topic: Crear plantilla ploteo
Replies: 1
Views: 209

Re: Crear plantilla ploteo

Querida Lourdes, Gracias por su pregunta. Hay información en Ayuda|Temas de Ayuda - User Manual -> Advanced Topics -> Editing Plot Templates que debería ayudarle. Además, también hay un tutorial paso a paso (Tutorials -> Plot Templates -> Edit an Existing Plot Template) para ayudarle a crear una pla...
by jovivier
Wed Feb 21, 2024 3:45 pm
Forum: Databases and Materials Selection
Topic: Addressing Nominal Pressure Alarm in Air Valves PN10 & PN16
Replies: 3
Views: 657

Re: Addressing Nominal Pressure Alarm in Air Valves PN10 & PN16

Hi Sergio, Unfortunately, we are not sure what you mean? Misc. Hydraulic items do not have pressure or pressure rating fields or warning messages. The only messages given would be above or below the flow limits or for PRVs when there is not enough upstream pressure. If you would like to send us an e...
by jovivier
Wed Feb 14, 2024 3:51 pm
Forum: Reports
Topic: Obtaining Plant Count and Area Report in Irricad
Replies: 2
Views: 465

Re: Obtaining Plant Count and Area Report in Irricad

There is actually a way to obtain a CSV report for the symbol count. The 'Symbol Count' function is a VCADD tool that is not utilised in IRRICAD therefore a script will need to be added. This is achieved via the CmdExt.vcdef file, located in your installed IRRICAD folder. Follow the process below:-...
by jovivier
Tue Feb 13, 2024 3:52 pm
Forum: Reports
Topic: Obtaining Plant Count and Area Report in Irricad
Replies: 2
Views: 465

Re: Obtaining Plant Count and Area Report in Irricad

Hi Sergio, In IRRICAD you are able to select items and obtain a "Count" count via the Info Panel, on the bottom right of the status bar. Unfortunately it isn't possible to obtain a report, such as a BOM, for non-hydraulic items. However, one method could be to make a copy of your design an...
by jovivier
Thu Feb 08, 2024 4:14 pm
Forum: Reports
Topic: Relatorio de materiais da zona
Replies: 2
Views: 501

Re: Relatorio de materiais da zona

Thank you for your question about partial Bill of Material reports. There are two ways to do this:- 1. A one-off report You can select the required zones on the screen, using the selection tools, and then action a BOM report. You also have the option to include a name for the report such "BOM f...
by jovivier
Mon Feb 05, 2024 3:47 pm
Forum: FAQs for IRRICAD Link
Topic: Management Symbol Placement Issue in BricsCAD V23
Replies: 0
Views: 538

Management Symbol Placement Issue in BricsCAD V23

In IRRICAD Link for BricsCAD v23 there is an issue placing the management symbol at large coordinates due to a change in BricsCAD. This has been partially fixed in the later versions of BricsCAD v23. If you cannot see the preview of the management symbol to place it please follow the below recommend...
by jovivier
Wed Jan 24, 2024 10:30 am
Forum: FAQs for IRRICAD Link
Topic: If IRRICAD Link for AutoCAD Hangs at the AutoCAD Splashscreen
Replies: 0
Views: 1167

If IRRICAD Link for AutoCAD Hangs at the AutoCAD Splashscreen

When trying to run IRRICAD Link for AutoCAD but it appears to hang at "Loading plug-ins C:\\Program Files\\Irricad\\Irricad Link AutoCad\\irricad64.arx\" and doesn't get past the AutoCAD splashscreen the likely cause is the dongle. 1. Check that the dongle is securely inserted into the USB...
by jovivier
Wed Jan 24, 2024 8:02 am
Forum: Miscellaneous
Topic: ERROR - 1111
Replies: 1
Views: 543

Re: ERROR - 1111

IRRICAD has been installed correctly, but the message means a “Dongle” emulator has been detected. These emulators are associated with illegal software and IRRICAD will not operate if one is found. The only solutions are:- 1) Remove the illegal software/emulator entirely from your system. If the emu...
by jovivier
Fri Jan 19, 2024 12:18 pm
Forum: Support FAQs
Topic: If Google Earth Import Stops Working
Replies: 1
Views: 16029

Re: If Google Earth Import Stops Working

The most recent method to update your credit card details is:- 1. Log into your Google Cloud Console - https://cloud.google.com/maps-platform/?authuser=2 , and if required, click on the [Get Started] button. 2. Access the "Billing" option from the main dropdown menu. 3. In the right-hand s...