In my drip irrigation projects I try to use a minimum inlet pressure so that the end has a final outlet pressure and minimum speed of 0.4m/s for system flushing.
Question: Using an "X" inlet pressure, how to check the minimum flow velocity at the end of the dripperline?
Is this possible on irricad?
Inlet pressure for minimum wash speed
-
- Posts: 59
- Joined: Sun Aug 23, 2020 7:07 am
- Company: Autônomo
- City / Town: Pratos de Minas
- Product: Irricad Standalone
Inlet pressure for minimum wash speed
You do not have the required permissions to view the files attached to this post.
- jovivier
- Site Admin
- Posts: 919
- Joined: Thu Mar 12, 2009 2:57 pm
- Company: Lincoln Agritech Ltd, IRRICAD Software
- City / Town: Lincoln
- Location: Canterbury, New Zealand
- Contact:
Re: Inlet pressure for minimum wash speed
Hi Marcio,
You can use the inbuilt flushing analysis. This will produce a flushing report that shows the velocity at the end of each tape.
If you are using Tape Irrigation Blocks you can set up the flushing manifolds in the "Flushing" tab. Otherwise use the "virtual" manifolds as per the Design|Design Parameters|Hydraulic Parameters - Flushing Parameters settings.
For the use of the flushing functions read Help|Help Topics - User Manual -> Management & Designing the System -> Flushing Calculations.
The IRRICAD Team
You can use the inbuilt flushing analysis. This will produce a flushing report that shows the velocity at the end of each tape.
If you are using Tape Irrigation Blocks you can set up the flushing manifolds in the "Flushing" tab. Otherwise use the "virtual" manifolds as per the Design|Design Parameters|Hydraulic Parameters - Flushing Parameters settings.
For the use of the flushing functions read Help|Help Topics - User Manual -> Management & Designing the System -> Flushing Calculations.
The IRRICAD Team
-
- Posts: 59
- Joined: Sun Aug 23, 2020 7:07 am
- Company: Autônomo
- City / Town: Pratos de Minas
- Product: Irricad Standalone
Re: Inlet pressure for minimum wash speed
ok Jovivier!
thank you very much for your attention always.
thank you very much for your attention always.
-
- Posts: 59
- Joined: Sun Aug 23, 2020 7:07 am
- Company: Autônomo
- City / Town: Pratos de Minas
- Product: Irricad Standalone
Re: Inlet pressure for minimum wash speed
Helo!
Trying to do it here, but in the report the final flow and final velocity are zeroed!
Could you help me?
The attached files follow.
Trying to do it here, but in the report the final flow and final velocity are zeroed!
Could you help me?
The attached files follow.
You do not have the required permissions to view the files attached to this post.
- jovivier
- Site Admin
- Posts: 919
- Joined: Thu Mar 12, 2009 2:57 pm
- Company: Lincoln Agritech Ltd, IRRICAD Software
- City / Town: Lincoln
- Location: Canterbury, New Zealand
- Contact:
Re: Inlet pressure for minimum wash speed
Hi Marcio,
You need to set the manifold number to flush in Zone Design Configuration. For the virtual manifolds this number will be a negative number - as you see in the reports.
For example to flush manifold -34 enter -34 in to the Manifold column for Bloco No. 1.
Note that only one manifold can be flushed at a time.
The IRRICAD Team
You need to set the manifold number to flush in Zone Design Configuration. For the virtual manifolds this number will be a negative number - as you see in the reports.
For example to flush manifold -34 enter -34 in to the Manifold column for Bloco No. 1.
Note that only one manifold can be flushed at a time.
The IRRICAD Team
-
- Posts: 59
- Joined: Sun Aug 23, 2020 7:07 am
- Company: Autônomo
- City / Town: Pratos de Minas
- Product: Irricad Standalone
Re: Inlet pressure for minimum wash speed
Hello Jovivier!
Perfect, now I get it.
Thanks again for your attention as always.
Perfect, now I get it.
Thanks again for your attention as always.
You do not have the required permissions to view the files attached to this post.