Helo! I would like to better understand when to check or uncheck this box: Allow for Minor Losses
You do not have the required permissions to view the files attached to this post.
User avatar
jovivier
Site Admin
Posts: 919
Joined: Thu Mar 12, 2009 2:57 pm
Company: Lincoln Agritech Ltd, IRRICAD Software
City / Town: Lincoln
Location: Canterbury, New Zealand
Contact:

Re: Allow for Minor Losses

Post by jovivier »

Dear Marcio,

This is explained in the manual, see Help|Help Topics - User Manual -> Advanced Topics -> Spraylines, Tapes and Minor Losses.

The IRRICAD Team
marcioagr
Posts: 59
Joined: Sun Aug 23, 2020 7:07 am
Company: Autônomo
City / Town: Pratos de Minas
Product: Irricad Standalone

Re: Allow for Minor Losses

Post by marcioagr »

OK!
Thanks.
aridzv
Posts: 38
Joined: Tue Jun 29, 2021 6:05 pm
Company: Independent
City / Town: Tel Yossef
Product: Irricad Link (BricsCAD)

Re: Allow for Minor Losses

Post by aridzv »

Hi.
About micro sprinklers -
I went over the minor losses in the User Manual > Advanced Topics, and the Outlets Connections chapter in the database help, and just to be sure I've got it right, I have tow questions as shown in the attached screenshot:
thanks,
Ari.
You do not have the required permissions to view the files attached to this post.
User avatar
jovivier
Site Admin
Posts: 919
Joined: Thu Mar 12, 2009 2:57 pm
Company: Lincoln Agritech Ltd, IRRICAD Software
City / Town: Lincoln
Location: Canterbury, New Zealand
Contact:

Re: Allow for Minor Losses

Post by jovivier »

Hi Ari,

1. Yes, the headloss in the outlet connector is calculated as a friction loss based on the HL equivalent length (total length) and HL equivalent diameter (ID) entered in the Outlet Connector in the database.

2. Minor losses for connections to pipes (outlet connectors or laterals) are based on the minor loss calculation as explained in the manual. The Kd is only used for internal emitters (tapes/dripline).

The IRRICAD Team