Multiple Water Supply Error

Discussions about hydraulic design.
Post Reply
Luzvstaicer
Posts: 4
Joined: Wed Jun 30, 2021 10:43 am
Company: AvidWater
City / Town: Fresno

Multiple Water Supply Error

Post by Luzvstaicer »

I have a system that has 4 water supplies that run 3 sets. When I try to add more than 2 of them, I get the IDE_DES_451: Root node out of range error. All water supplies have pressures specified.
Is there something I can try to see if I can make it work?
Is this something that is too complex for Irricad?

Thank you.
seng
Posts: 13
Joined: Thu Sep 18, 2014 8:34 am
Company: Spare Engineering
City / Town: Hesston, Kansas
Product: Irricad Link (BricsCAD)

Re: Multiple Water Supply Error

Post by seng »

Hi Luz,
Please check that your water supplies are not located at inline positions-- they are only allowed to have one pipe attached to them. Secondly, be sure to note the difference between pumps and water supplies as IRRICAD defines them. The Help section gives important information there.
Regards,
Dan