Lateral pipe sizes in Spray Blocks

Discussions about hydraulic design.
Post Reply
David Wright
Posts: 9
Joined: Mon Aug 13, 2012 7:07 pm
Company: Rivulis
City / Town: Brisbane
Product: Irricad Standalone

Lateral pipe sizes in Spray Blocks

Post by David Wright »

I am running a design using Spray Block Entities and have reached a solution using 32 and 25mm LDPE for the laterals. The length of the 32mm poly varies between 85 and 97m for each lateral. Is there a way to adjust the 32mm so that all laterals use 100m, to make practical installation in the field easier, without having to explode the block?
Gilary
Posts: 13
Joined: Tue May 05, 2009 5:12 pm
Company: NETAFIM
City / Town: MAGAL

Re: Lateral pipe sizes in Spray Blocks

Post by Gilary »

You can use the tool "Move Sizes"
Create the line 100m from the submain and arrange according the 32mm pipe
David Wright
Posts: 9
Joined: Mon Aug 13, 2012 7:07 pm
Company: Rivulis
City / Town: Brisbane
Product: Irricad Standalone

Re: Lateral pipe sizes in Spray Blocks

Post by David Wright »

Yes this works well. How long has that been there? You learn something new every day!
Thanks
Gilary
Posts: 13
Joined: Tue May 05, 2009 5:12 pm
Company: NETAFIM
City / Town: MAGAL

Re: Lateral pipe sizes in Spray Blocks

Post by Gilary »

I assume it is more than 10 years there
Post Reply