Search found 927 matches

by jovivier
Fri Jun 13, 2025 10:01 am
Forum: Announcements
Topic: New Patch for IRRICAD Standalone V22 (22.05)
Replies: 0
Views: 115

New Patch for IRRICAD Standalone V22 (22.05)

The 22.05 patch for Version 22 is now available. This patch contains a few additions and bug fixes. See https://www.irricad.com/irricad/download/Upgrade/Prov10/Readme.txt. Most notably, the improper argument issue for graphical management when blocks contain extra items has been fixed, changes to ...
by jovivier
Thu May 29, 2025 2:22 pm
Forum: Databases and Materials Selection
Topic: Material Detailing
Replies: 1
Views: 379

Re: Material Detailing

Hi JP,

If you are talking about 'assemblies', meaning a specific group of items to be selected together, then you may be interested in the "Creating and Modifying Assemblies" tutorial located in Help|Help Topics - Tutorials -> Database and Fitting Selection.

Additionally you may find IRRICAD ...
by jovivier
Wed May 28, 2025 3:14 pm
Forum: Reports
Topic: Zone Travel Time Report for 'Longest Total Time' Lateral Only
Replies: 0
Views: 421

Zone Travel Time Report for 'Longest Total Time' Lateral Only

A Zone travel time report which only displays the 'longest total time' lateral can be downloaded from https://www.irricad.com/irricad/download/help/files/ZONEDESIGNTRAVELSUMM.zip .

Save the zip file to your local drive and double-click on it to open.
Drag the FPC file out of the zip file into your ...
by jovivier
Mon May 19, 2025 4:42 pm
Forum: Hydraulic Design
Topic: Static Pressure Labels
Replies: 1
Views: 640

Re: Static Pressure Labels

To find the max static pressure at each mainline outlet in the gravity system you want to mirror the least amount of friction loss when there is flow.
If you add a Mainline outlet with a very small flow that runs on its own system flow, you will be able to capture the max static pressure at the real ...
by jovivier
Thu May 15, 2025 5:00 pm
Forum: Hydraulic Design
Topic: Row Count for Valve Locations Label
Replies: 1
Views: 389

Re: Row Count for Valve Locations Label

Hi Steve,

Currently there isn't a way for the labels to 'count' the rows to the valve position.
Because valves can be connected directly the submain or on a stalk, or submains may have branches in them it may be quite difficult to program for this.
The only automatic location option presently is to ...
by jovivier
Mon May 05, 2025 5:09 pm
Forum: Hydraulic Design
Topic: Error message
Replies: 8
Views: 14716

Re: Error message

Hi Nawar,

Are you receiving the message "Branches or bends not allowed..."? Where you have a submain transecting a dripline this will not cause the message however additional junctions, tapes feeding into other tapes, a Misc. Hydraulic item on a tape, or an additional submain will cause this ...
by jovivier
Mon Apr 28, 2025 4:42 pm
Forum: Hydraulic Design
Topic: is it possible to create irrigation block with "groups of groups" like in greenhouses?
Replies: 1
Views: 1614

Re: is it possible to create irrigation block with "groups of groups" like in greenhouses?

Hi Ari,

The Irrigation Block tools only allow for one set of grouping.
You would have to make each "6 sets of 3 laterals" as one irrigation block, without an automatic valve placement, and then feed all 10 irrigation blocks from one manually placed valve. Therefore you still only have the one zone ...
by jovivier
Wed Apr 16, 2025 3:21 pm
Forum: Databases and Materials Selection
Topic: Zero diameter or zero HW constant message...
Replies: 2
Views: 3012

Re: Zero diameter or zero HW constant message...

Hi Pablo,

One way to find the pipe in question is to use the "Query" in the Database Editor.
The tab can be found after the "Nozzles" tab, after being turn on via Tools|Options - enable the "Show Query tab" option.
Once in the Query tab you can load standard queries from the dropdown or you can ...
by jovivier
Fri Apr 11, 2025 2:11 pm
Forum: Announcements
Topic: IRRICAD Version 22 Standalone Has Been Released!
Replies: 0
Views: 3128

IRRICAD Version 22 Standalone Has Been Released!

It’s here! We are excited to announce that IRRICAD™ Standalone Version 22 has been released and is available through your local distributor.

Keeping your version of IRRICAD™ up to date ensures that you will continue to be provided with all the latest features, priority support, and upgrades.
If you ...
by jovivier
Fri Apr 04, 2025 12:53 pm
Forum: Hydraulic Design
Topic: "Branches or bends in tapes or drip lines are not allowed"
Replies: 1
Views: 1640

Re: "Branches or bends in tapes or drip lines are not allowed"

Hi Nawar,

In Version 21 and older versions, a tape cannot have more than one connection. As long as the tape is a 'polyline' it can have bends in it but once additional junctions or connections are present you will receive the message. In these cases the tapes will not be able to be drawn exactly ...
by jovivier
Fri Mar 21, 2025 12:46 pm
Forum: CAD Drawing
Topic: Keyboard shortcuts
Replies: 5
Views: 5024

Re: Keyboard shortcuts

Thanks Nick. Gaby is working with IRRICAD Standalone rather than with IRRICAD Link. The @ symbol will not work in IRRICAD Standalone.

The IRRICAD Team
by jovivier
Mon Mar 17, 2025 1:27 pm
Forum: Hydraulic Design
Topic: main line valves open/close by system flow?
Replies: 2
Views: 2152

Re: main line valves open/close by system flow?

Hi Ari,

Misc. Hydraulic items do not have an on/off function and cannot determine what is included in a system flow.

To analyse the system when the isolating valve is closed you will need to ensure that no zones downstream from the isolating valve are included in the system flows.
One method to ...
by jovivier
Mon Mar 17, 2025 10:29 am
Forum: Miscellaneous
Topic: ERROR - SENT 3
Replies: 3
Views: 5702

Re: ERROR - SENT 3

If this error is followed by additional errors please email your local support team for direct assistance.

The IRRICAD Team.
by jovivier
Fri Mar 14, 2025 1:00 pm
Forum: Importing and Exporting
Topic: Units error...
Replies: 1
Views: 3036

Re: Units error...

Hi Pancho,

In IRRICAD Standalone check Settings|Import/Export Settings .
The dialog will display the "Import Settings" and the "Export Settings".
For the "Export Settings" is the "Base Export Unit" set to Feet ?
If so, change this option to Meter and export to .Daz file again.

If this does not ...
by jovivier
Tue Mar 11, 2025 10:24 am
Forum: Databases and Materials Selection
Topic: computer selection fittings
Replies: 7
Views: 6279

Re: computer selection fittings

Hi Davie,

When the lateral is on the end of a submain (where there is no submain stub beyond the end laterals) IRRICAD will look for a bend/elbow to connect the submain to the lateral.

To fix this, there are two solutions:-
1. Enter or enable the required fittings to go from the 50mm submain to ...
by jovivier
Fri Feb 21, 2025 4:09 pm
Forum: CAD Drawing
Topic: Adding details to plot layout
Replies: 1
Views: 1796

Re: Adding details to plot layout

Hi Jarrad,

Thank you for your questions.

1) You can draw a scale bar and save it as a symbol. This can be saved in the plot template via the Plot Template menu commands.
See Help|Help Topics for information about making symbols and editing the Plot Templates.

2) You can copy and paste this on to ...
by jovivier
Tue Feb 18, 2025 1:22 pm
Forum: Announcements
Topic: New Patch for IRRICAD Link Version 21
Replies: 0
Views: 2072

New Patch for IRRICAD Link Version 21

The new Patch for IRRICAD Link V21 is now available - v21.XX.34

This patch contains a few additions and bug fixes. See https://www.irricad.com/irricad/download/upgrade/Link/Readme.txt for more information.

To apply, go to IRR_CHECKUPDATES in IRRICAD Link V21 and then to proceed, click [Next]. The ...
by jovivier
Thu Feb 13, 2025 9:16 am
Forum: Suggestions
Topic: Hand select Pipe code
Replies: 4
Views: 3791

Re: Hand select Pipe code

Hi Nick,

Please note that any additions made since Version 16 will be in the Release Notes. However, the addition of the "S" usage code was added in a later patch for Version 20 so does not appear in the V20 Release Notes.

The Readme says: A new usage flag "S" (specify) has been added for pipes ...
by jovivier
Thu Feb 13, 2025 8:39 am
Forum: Suggestions
Topic: Hand select Pipe code
Replies: 4
Views: 3791

Re: Hand select Pipe code

Hi Nick,

Please note that there is already a usage code for what you require. It is "S" for mainline pipes that can only be manually selected.
("F" is the equivalent zone pipe usage code).

The IRRICAD Team
by jovivier
Fri Feb 07, 2025 8:20 am
Forum: Miscellaneous
Topic: Rain Bird database
Replies: 2
Views: 2834

Re: Rain Bird database

Hi Nawar,

Thank you for your interest in an updated Rain Bird database.
We have been recently emailing with Rain Bird about available options.

The IRRICAD Team