Search found 927 matches
- Fri Jun 13, 2025 10:01 am
- Forum: Announcements
- Topic: New Patch for IRRICAD Standalone V22 (22.05)
- Replies: 0
- Views: 115
New Patch for IRRICAD Standalone V22 (22.05)
The 22.05 patch for Version 22 is now available. This patch contains a few additions and bug fixes. See https://www.irricad.com/irricad/download/Upgrade/Prov10/Readme.txt. Most notably, the improper argument issue for graphical management when blocks contain extra items has been fixed, changes to ...
- Thu May 29, 2025 2:22 pm
- Forum: Databases and Materials Selection
- Topic: Material Detailing
- Replies: 1
- Views: 379
Re: Material Detailing
Hi JP,
If you are talking about 'assemblies', meaning a specific group of items to be selected together, then you may be interested in the "Creating and Modifying Assemblies" tutorial located in Help|Help Topics - Tutorials -> Database and Fitting Selection.
Additionally you may find IRRICAD ...
If you are talking about 'assemblies', meaning a specific group of items to be selected together, then you may be interested in the "Creating and Modifying Assemblies" tutorial located in Help|Help Topics - Tutorials -> Database and Fitting Selection.
Additionally you may find IRRICAD ...
- Wed May 28, 2025 3:14 pm
- Forum: Reports
- Topic: Zone Travel Time Report for 'Longest Total Time' Lateral Only
- Replies: 0
- Views: 421
Zone Travel Time Report for 'Longest Total Time' Lateral Only
A Zone travel time report which only displays the 'longest total time' lateral can be downloaded from https://www.irricad.com/irricad/download/help/files/ZONEDESIGNTRAVELSUMM.zip .
Save the zip file to your local drive and double-click on it to open.
Drag the FPC file out of the zip file into your ...
Save the zip file to your local drive and double-click on it to open.
Drag the FPC file out of the zip file into your ...
- Mon May 19, 2025 4:42 pm
- Forum: Hydraulic Design
- Topic: Static Pressure Labels
- Replies: 1
- Views: 640
Re: Static Pressure Labels
To find the max static pressure at each mainline outlet in the gravity system you want to mirror the least amount of friction loss when there is flow.
If you add a Mainline outlet with a very small flow that runs on its own system flow, you will be able to capture the max static pressure at the real ...
If you add a Mainline outlet with a very small flow that runs on its own system flow, you will be able to capture the max static pressure at the real ...
- Thu May 15, 2025 5:00 pm
- Forum: Hydraulic Design
- Topic: Row Count for Valve Locations Label
- Replies: 1
- Views: 389
Re: Row Count for Valve Locations Label
Hi Steve,
Currently there isn't a way for the labels to 'count' the rows to the valve position.
Because valves can be connected directly the submain or on a stalk, or submains may have branches in them it may be quite difficult to program for this.
The only automatic location option presently is to ...
Currently there isn't a way for the labels to 'count' the rows to the valve position.
Because valves can be connected directly the submain or on a stalk, or submains may have branches in them it may be quite difficult to program for this.
The only automatic location option presently is to ...
- Mon May 05, 2025 5:09 pm
- Forum: Hydraulic Design
- Topic: Error message
- Replies: 8
- Views: 14716
Re: Error message
Hi Nawar,
Are you receiving the message "Branches or bends not allowed..."? Where you have a submain transecting a dripline this will not cause the message however additional junctions, tapes feeding into other tapes, a Misc. Hydraulic item on a tape, or an additional submain will cause this ...
Are you receiving the message "Branches or bends not allowed..."? Where you have a submain transecting a dripline this will not cause the message however additional junctions, tapes feeding into other tapes, a Misc. Hydraulic item on a tape, or an additional submain will cause this ...
- Mon Apr 28, 2025 4:42 pm
- Forum: Hydraulic Design
- Topic: is it possible to create irrigation block with "groups of groups" like in greenhouses?
- Replies: 1
- Views: 1614
Re: is it possible to create irrigation block with "groups of groups" like in greenhouses?
Hi Ari,
The Irrigation Block tools only allow for one set of grouping.
You would have to make each "6 sets of 3 laterals" as one irrigation block, without an automatic valve placement, and then feed all 10 irrigation blocks from one manually placed valve. Therefore you still only have the one zone ...
The Irrigation Block tools only allow for one set of grouping.
You would have to make each "6 sets of 3 laterals" as one irrigation block, without an automatic valve placement, and then feed all 10 irrigation blocks from one manually placed valve. Therefore you still only have the one zone ...
- Wed Apr 16, 2025 3:21 pm
- Forum: Databases and Materials Selection
- Topic: Zero diameter or zero HW constant message...
- Replies: 2
- Views: 3012
Re: Zero diameter or zero HW constant message...
Hi Pablo,
One way to find the pipe in question is to use the "Query" in the Database Editor.
The tab can be found after the "Nozzles" tab, after being turn on via Tools|Options - enable the "Show Query tab" option.
Once in the Query tab you can load standard queries from the dropdown or you can ...
One way to find the pipe in question is to use the "Query" in the Database Editor.
The tab can be found after the "Nozzles" tab, after being turn on via Tools|Options - enable the "Show Query tab" option.
Once in the Query tab you can load standard queries from the dropdown or you can ...
- Fri Apr 11, 2025 2:11 pm
- Forum: Announcements
- Topic: IRRICAD Version 22 Standalone Has Been Released!
- Replies: 0
- Views: 3128
IRRICAD Version 22 Standalone Has Been Released!
It’s here! We are excited to announce that IRRICAD™ Standalone Version 22 has been released and is available through your local distributor.
Keeping your version of IRRICAD™ up to date ensures that you will continue to be provided with all the latest features, priority support, and upgrades.
If you ...
Keeping your version of IRRICAD™ up to date ensures that you will continue to be provided with all the latest features, priority support, and upgrades.
If you ...
- Fri Apr 04, 2025 12:53 pm
- Forum: Hydraulic Design
- Topic: "Branches or bends in tapes or drip lines are not allowed"
- Replies: 1
- Views: 1640
Re: "Branches or bends in tapes or drip lines are not allowed"
Hi Nawar,
In Version 21 and older versions, a tape cannot have more than one connection. As long as the tape is a 'polyline' it can have bends in it but once additional junctions or connections are present you will receive the message. In these cases the tapes will not be able to be drawn exactly ...
In Version 21 and older versions, a tape cannot have more than one connection. As long as the tape is a 'polyline' it can have bends in it but once additional junctions or connections are present you will receive the message. In these cases the tapes will not be able to be drawn exactly ...
- Fri Mar 21, 2025 12:46 pm
- Forum: CAD Drawing
- Topic: Keyboard shortcuts
- Replies: 5
- Views: 5024
Re: Keyboard shortcuts
Thanks Nick. Gaby is working with IRRICAD Standalone rather than with IRRICAD Link. The @ symbol will not work in IRRICAD Standalone.
The IRRICAD Team
The IRRICAD Team
- Mon Mar 17, 2025 1:27 pm
- Forum: Hydraulic Design
- Topic: main line valves open/close by system flow?
- Replies: 2
- Views: 2152
Re: main line valves open/close by system flow?
Hi Ari,
Misc. Hydraulic items do not have an on/off function and cannot determine what is included in a system flow.
To analyse the system when the isolating valve is closed you will need to ensure that no zones downstream from the isolating valve are included in the system flows.
One method to ...
Misc. Hydraulic items do not have an on/off function and cannot determine what is included in a system flow.
To analyse the system when the isolating valve is closed you will need to ensure that no zones downstream from the isolating valve are included in the system flows.
One method to ...
- Mon Mar 17, 2025 10:29 am
- Forum: Miscellaneous
- Topic: ERROR - SENT 3
- Replies: 3
- Views: 5702
Re: ERROR - SENT 3
If this error is followed by additional errors please email your local support team for direct assistance.
The IRRICAD Team.
The IRRICAD Team.
- Fri Mar 14, 2025 1:00 pm
- Forum: Importing and Exporting
- Topic: Units error...
- Replies: 1
- Views: 3036
Re: Units error...
Hi Pancho,
In IRRICAD Standalone check Settings|Import/Export Settings .
The dialog will display the "Import Settings" and the "Export Settings".
For the "Export Settings" is the "Base Export Unit" set to Feet ?
If so, change this option to Meter and export to .Daz file again.
If this does not ...
In IRRICAD Standalone check Settings|Import/Export Settings .
The dialog will display the "Import Settings" and the "Export Settings".
For the "Export Settings" is the "Base Export Unit" set to Feet ?
If so, change this option to Meter and export to .Daz file again.
If this does not ...
- Tue Mar 11, 2025 10:24 am
- Forum: Databases and Materials Selection
- Topic: computer selection fittings
- Replies: 7
- Views: 6279
Re: computer selection fittings
Hi Davie,
When the lateral is on the end of a submain (where there is no submain stub beyond the end laterals) IRRICAD will look for a bend/elbow to connect the submain to the lateral.
To fix this, there are two solutions:-
1. Enter or enable the required fittings to go from the 50mm submain to ...
When the lateral is on the end of a submain (where there is no submain stub beyond the end laterals) IRRICAD will look for a bend/elbow to connect the submain to the lateral.
To fix this, there are two solutions:-
1. Enter or enable the required fittings to go from the 50mm submain to ...
- Fri Feb 21, 2025 4:09 pm
- Forum: CAD Drawing
- Topic: Adding details to plot layout
- Replies: 1
- Views: 1796
Re: Adding details to plot layout
Hi Jarrad,
Thank you for your questions.
1) You can draw a scale bar and save it as a symbol. This can be saved in the plot template via the Plot Template menu commands.
See Help|Help Topics for information about making symbols and editing the Plot Templates.
2) You can copy and paste this on to ...
Thank you for your questions.
1) You can draw a scale bar and save it as a symbol. This can be saved in the plot template via the Plot Template menu commands.
See Help|Help Topics for information about making symbols and editing the Plot Templates.
2) You can copy and paste this on to ...
- Tue Feb 18, 2025 1:22 pm
- Forum: Announcements
- Topic: New Patch for IRRICAD Link Version 21
- Replies: 0
- Views: 2072
New Patch for IRRICAD Link Version 21
The new Patch for IRRICAD Link V21 is now available - v21.XX.34
This patch contains a few additions and bug fixes. See https://www.irricad.com/irricad/download/upgrade/Link/Readme.txt for more information.
To apply, go to IRR_CHECKUPDATES in IRRICAD Link V21 and then to proceed, click [Next]. The ...
This patch contains a few additions and bug fixes. See https://www.irricad.com/irricad/download/upgrade/Link/Readme.txt for more information.
To apply, go to IRR_CHECKUPDATES in IRRICAD Link V21 and then to proceed, click [Next]. The ...
- Thu Feb 13, 2025 9:16 am
- Forum: Suggestions
- Topic: Hand select Pipe code
- Replies: 4
- Views: 3791
Re: Hand select Pipe code
Hi Nick,
Please note that any additions made since Version 16 will be in the Release Notes. However, the addition of the "S" usage code was added in a later patch for Version 20 so does not appear in the V20 Release Notes.
The Readme says: A new usage flag "S" (specify) has been added for pipes ...
Please note that any additions made since Version 16 will be in the Release Notes. However, the addition of the "S" usage code was added in a later patch for Version 20 so does not appear in the V20 Release Notes.
The Readme says: A new usage flag "S" (specify) has been added for pipes ...
- Thu Feb 13, 2025 8:39 am
- Forum: Suggestions
- Topic: Hand select Pipe code
- Replies: 4
- Views: 3791
Re: Hand select Pipe code
Hi Nick,
Please note that there is already a usage code for what you require. It is "S" for mainline pipes that can only be manually selected.
("F" is the equivalent zone pipe usage code).
The IRRICAD Team
Please note that there is already a usage code for what you require. It is "S" for mainline pipes that can only be manually selected.
("F" is the equivalent zone pipe usage code).
The IRRICAD Team
- Fri Feb 07, 2025 8:20 am
- Forum: Miscellaneous
- Topic: Rain Bird database
- Replies: 2
- Views: 2834
Re: Rain Bird database
Hi Nawar,
Thank you for your interest in an updated Rain Bird database.
We have been recently emailing with Rain Bird about available options.
The IRRICAD Team
Thank you for your interest in an updated Rain Bird database.
We have been recently emailing with Rain Bird about available options.
The IRRICAD Team