Rationalization Parameters

Discussions about hydraulic design.
Post Reply
Smccoon
Posts: 7
Joined: Tue Jun 09, 2009 7:04 am
Company: Nelson Irrigation Corporation
City / Town: Walla Walla, WA. USA
Location: Walla Walla, WA. USA

Rationalization Parameters

Post by Smccoon »

In Version 17, in Design Parameters, Hydraulic Parameters, and Rationalization Parameters, I see the ability to use zone and mainline pipe pressure ratings in the design process. I know the pressure ratings are located in the pipe database. My question is, what pressure for a particular pipe in the pipe database field "Allowable Pressure" do I enter, and how is that number used in the rationalization process. For example, if I put an allowable pressure of 100 psi in the database, does the rationalization process switch to a heavier walled pipe at 100 psi, or at a percentage of 100 psi?
User avatar
jovivier
Site Admin
Posts: 924
Joined: Thu Mar 12, 2009 2:57 pm
Company: Lincoln Agritech Ltd, IRRICAD Software
City / Town: Lincoln
Location: Canterbury, New Zealand
Contact:

Re: Rationalization Parameters

Post by jovivier »

Hi Steve,

There is no tolerance built into this setting, therefore if your allowable pressure is set to 100psi then any pipe pressures greater than 100psi will cause an automatic change to a suitable pipe size rated at over 100psi during LP or Velocity designing.

The IRRICAD Team