Search found 11 matches

by Rob Leng
Wed May 04, 2011 6:07 pm
Forum: Suggestions
Topic: Aligning contour labels
Replies: 1
Views: 5874

Aligning contour labels

I would like to see a feature developed that allowed you to align contour labels in a line so you did not have to search for the labels across the entire design area, ie. if you could draw a verticle (or other angle) line across contour lines and nominate the intersection point of the line and the c...
by Rob Leng
Fri Apr 15, 2011 3:55 pm
Forum: Suggestions
Topic: Pipe reduction symbol
Replies: 16
Views: 29987

Re: Pipe reduction symbol

Happy to see action on this, thanks Dan. In answer to your questions 1. I have found that a filled black triangle (slightly elongated in the pointing direction) is best. 2. No 3. Yes 4. I always reduce downstream of an elbow rather than upstream as this is a hydraulically superior method in regard t...
by Rob Leng
Thu Mar 10, 2011 3:37 pm
Forum: Miscellaneous
Topic: Creating a new line style
Replies: 3
Views: 7945

Creating a new line style

Is it possible to create a new customised line style? I do not find any of the existing line styles distinctive/suitable for represnting a fence and fences are a common feature on my plans. Additionally, If it were possible to have certain (selected via check box) line styles and their names appear ...
by Rob Leng
Wed Sep 22, 2010 12:14 pm
Forum: Miscellaneous
Topic: Layers stability
Replies: 2
Views: 6529

Layers stability

I am running version 10.52.I have been having problems with stability issues in regard to layers (not to mention irricad dongle stability). For example i was just adding some text to a design and when i placed the text it was not visible, so i thought maybe i did not click the mouse correctly so i c...
by Rob Leng
Sat Aug 14, 2010 12:11 pm
Forum: Miscellaneous
Topic: Data base
Replies: 1
Views: 4987

Data base

Is there any reason why the Warehouse Code in the data base is restricted to 12 letters? I find this is a problem as many of the codes suppliers have for their products exceed this limit.
by Rob Leng
Fri Jun 04, 2010 12:27 pm
Forum: Reports
Topic: Creating & modifying reports
Replies: 1
Views: 8842

Creating & modifying reports

I would like to have a look at creating & modifying irricad reports but i do not know where to start. Is there any tutorials available on this?
by Rob Leng
Fri Jun 04, 2010 12:19 pm
Forum: Reports
Topic: Pump Duty Report
Replies: 3
Views: 12474

Re: Pump Duty Report

Gday Phil,
Thanks for the report, just had a play with it & it looks good.

Sorry for not replying sooner, i have not been on the forum for a while.

One thing though the pump name is not enabled in the report, it would be good to have that fixed if possible.

Thanks again, Rob.
by Rob Leng
Fri Feb 19, 2010 2:48 pm
Forum: Reports
Topic: Pump Duty Report
Replies: 3
Views: 12474

Pump Duty Report

Currently when using a pump in a design there is no pump duty report available for the design. When you view the system duty report the pressure reported for the design is simply the pressure that you must enter into the water supply (ie -1) for irricad to work when using a pump. This is not the tru...
by Rob Leng
Fri Jan 29, 2010 11:39 am
Forum: Suggestions
Topic: Text background
Replies: 0
Views: 4369

Text background

An option to have a background fill for the "draw text" tool (as is available with labels) would be a handy addition to help text stand out clearly when required ie. when placing text across laterals on a tape block entity where it is quite often hard to read. This option would also be gre...
by Rob Leng
Thu Jan 28, 2010 3:41 pm
Forum: Suggestions
Topic: Automatic submain flush valve
Replies: 4
Views: 11511

Automatic submain flush valve

It would be good to have the option of selecting a submain flush valve for the end(s) of a submain incorporated into the "tape irrigation block" tool along the same lines as is available in the flushing section of this tool.
by Rob Leng
Wed Jul 08, 2009 1:27 pm
Forum: Suggestions
Topic: Pipe reduction symbol
Replies: 16
Views: 29987

Pipe reduction symbol

It would be very beneficial to have a pipe reduction symbol (filled triangle as arrow preferrably) automatically generated at pipe reductions in mainlines, submains & laterals. This should be a selectable option for the printed design plan or on its own layer. Based on feedback from installation...