How to Use Minimum and maximum Allowable Pressure

Discussions about hydraulic design.
Post Reply
crovello
Posts: 15
Joined: Fri Jan 09, 2015 3:09 am
Company: Netafim
City / Town: Netafim

How to Use Minimum and maximum Allowable Pressure

Post by crovello »

hi, i want to ask you how i can use the aplication minimum and maximum allowabe pressure, in the zone design configuration.

Because i matched this item, but nothing occur in zone desing, i think someting i did wrong.

please help me.

thenks for everything.

:geek: :geek: :geek:
You do not have the required permissions to view the files attached to this post.
User avatar
jovivier
Site Admin
Posts: 919
Joined: Thu Mar 12, 2009 2:57 pm
Company: Lincoln Agritech Ltd, IRRICAD Software
City / Town: Lincoln
Location: Canterbury, New Zealand
Contact:

Re: How to Use Minimum and maximum Allowable Pressure

Post by jovivier »

Hi,

The "Minimum Allowable Pressure" and "Maximum Allowable Pressure" options in the Zone Design Configuration table allow you to specify a different minimum and maximum allowable pressure than the tolerance specified in the database for the outlet or tape.

This is handy for situations where you would like to use a different tolerance range than normal without having to change the parameters in the database for the rare situation.
For these inputted values to work remember to enable the "Don't Use Database Envelope" check box.

The IRRICAD Team