Dear Irricad Team,
Nedd help with this ,I get the following errors:
1 DES 473: Valve /WS pressure not specified for detail analysis
2.DES 416: Zon Design has not been completed
Thanks with Regards
DES-473/416
-
- Posts: 1
- Joined: Tue Nov 06, 2018 2:46 pm
- Company: Hahaha Agritech
- City / Town: Klung
- Product: Irricad Standalone
- phil
- Site Admin
- Posts: 41
- Joined: Wed Apr 29, 2009 11:48 am
- Company: Lincoln Agritech Ltd.
- City / Town: Christchurch
- Location: Lincoln, New Zealand
- Contact:
Re: DES-473/416
Detailed analysis requires that the control valve pressure is specified and this warning indicates that this hasn't been done. Control Valve pressures for each zone may be entered in "Design/Zone Design Configuration" - more information is available in the IRRICAD manual ("Help/Help Topics").
Note that the 416 error is simply a consequence of zone design not having completed.
Note that the 416 error is simply a consequence of zone design not having completed.