DES-473/416

Discussions about hydraulic design.
Post Reply
Hahaha Agritech
Posts: 1
Joined: Tue Nov 06, 2018 2:46 pm
Company: Hahaha Agritech
City / Town: Klung
Product: Irricad Standalone

DES-473/416

Post by Hahaha Agritech »

Dear Irricad Team,

Nedd help with this ,I get the following errors:

1 DES 473: Valve /WS pressure not specified for detail analysis
2.DES 416: Zon Design has not been completed


Thanks with Regards
User avatar
phil
Site Admin
Posts: 41
Joined: Wed Apr 29, 2009 11:48 am
Company: Lincoln Agritech Ltd.
City / Town: Christchurch
Location: Lincoln, New Zealand
Contact:

Re: DES-473/416

Post by phil »

Detailed analysis requires that the control valve pressure is specified and this warning indicates that this hasn't been done. Control Valve pressures for each zone may be entered in "Design/Zone Design Configuration" - more information is available in the IRRICAD manual ("Help/Help Topics").

Note that the 416 error is simply a consequence of zone design not having completed.
Post Reply