Pump Calc

Discussion about zone, mainline, management, costing and bill of materials reports.
Post Reply
turbofergy
Posts: 37
Joined: Mon Jul 18, 2016 5:38 pm
Company: Ferguson Irrigation Solutions and Techno
City / Town: Bundaberg

Pump Calc

Post by turbofergy »

Hello

When doing a pump duty report my mainline losses show up as a negative but the filtration losses etc are a positive number.

Thanks

Kyle
User avatar
jovivier
Site Admin
Posts: 919
Joined: Thu Mar 12, 2009 2:57 pm
Company: Lincoln Agritech Ltd, IRRICAD Software
City / Town: Lincoln
Location: Canterbury, New Zealand
Contact:

Re: Pump Calc

Post by jovivier »

Hi Kyle,

Which report are you using?

The IRRICAD Team
turbofergy
Posts: 37
Joined: Mon Jul 18, 2016 5:38 pm
Company: Ferguson Irrigation Solutions and Techno
City / Town: Bundaberg

Re: Pump Calc

Post by turbofergy »

I am using OLE Pump duty Calc.

Thanks

Kyle
User avatar
jovivier
Site Admin
Posts: 919
Joined: Thu Mar 12, 2009 2:57 pm
Company: Lincoln Agritech Ltd, IRRICAD Software
City / Town: Lincoln
Location: Canterbury, New Zealand
Contact:

Re: Pump Calc

Post by jovivier »

Hi Kyle,

Please email your custom report template and design to Support@IRRICAD.com.

The IRRICAD Team
Post Reply