Hello everyone, I am making a sprinkler design in a terrain with a lot of height difference, the drawback is that the flow of each emitter is the same despite the difference in elevation between them and the respective dynamic pressure.
To add, the configuration is set up as a non pc sprinkler.
Flow variation vs. topographical differenc
-
- Posts: 63
- Joined: Thu Feb 05, 2015 7:00 am
- Company: indep
- City / Town: Guayaquil
Flow variation vs. topographical differenc
-----------------------------
Miguel Loaiza Espinoza
Irrigation Designer
Mloaiza@magap.gob.ec
Mloaiza06@gmail.com
Mob +593-989842755
Miguel Loaiza Espinoza
Irrigation Designer
Mloaiza@magap.gob.ec
Mloaiza06@gmail.com
Mob +593-989842755
- jovivier
- Site Admin
- Posts: 919
- Joined: Thu Mar 12, 2009 2:57 pm
- Company: Lincoln Agritech Ltd, IRRICAD Software
- City / Town: Lincoln
- Location: Canterbury, New Zealand
- Contact:
Re: Flow variation vs. topographical differenc
Dear Miguel,
When using non-pressure compensating sprinklers it is important to set the valve pressure in Design|Zone Design Configuration and run Zone Design|Detailed Analysis. This is when IRRICAD calculates the exact pressure at each emitter and the resulting flow, and it requires the valve pressure in order to do this. The normal Analyze function will only provide the flow as expected from the nominal pressure entered into the outlet / sprayline dialog.
See our "Tips forum post "30. UNDERSTANDING DETAILED ANALYSIS" (viewtopic.php?p=577#p577) for more information.
The IRRICAD Team
When using non-pressure compensating sprinklers it is important to set the valve pressure in Design|Zone Design Configuration and run Zone Design|Detailed Analysis. This is when IRRICAD calculates the exact pressure at each emitter and the resulting flow, and it requires the valve pressure in order to do this. The normal Analyze function will only provide the flow as expected from the nominal pressure entered into the outlet / sprayline dialog.
See our "Tips forum post "30. UNDERSTANDING DETAILED ANALYSIS" (viewtopic.php?p=577#p577) for more information.
The IRRICAD Team
-
- Posts: 63
- Joined: Thu Feb 05, 2015 7:00 am
- Company: indep
- City / Town: Guayaquil
Re: Flow variation vs. topographical differenc
Thanks for the answer Jo
-----------------------------
Miguel Loaiza Espinoza