The key words are:
#DESC# - Description field from the database.
#DIA1# - First diameter field from database (nominal for pipes /tapes, inlet, major etc.)
#DIA2# - Second diameter field from database (actual for pipes/tapes, outlet, minor etc.)
#DIAUNIT# - Current unit selected for diameters (mm, inch etc.).
#ELEV# - Elevation of item, applies to point items and contours only.
#ELEVUNIT# - Current unit of elevation.
#LABEL# - Label field from database (for primary item).
#LENGTH# - 2D length of item, applies only to pipes, tapes, wires.
#LENGTH3D# - 3D length of item, applies only to pipes, tapes, wires.
#ROLLS# - 2D pipe lengths as a number of rolls based on the roll length of the pipe type in the Pipe Fitting Matching Table.
#ROLLS3D# - 3D pipe lengths as a number of rolls based on the roll length of the pipe type in the Pipe Fitting Matching Table.
#LENUNIT# - Current unit of length.
#NAME# - Zone or Water Supply name.
#NOZDESC# - Nozzle description, applies to connected spraylines only.
#NOZLABEL# - Nozzle label, applies to connected spraylines only.
#OUTDESC# - Outlet description, applies to connected spraylines only.
#OUTLABEL# - Outlet label, applies to connected spraylines only.
#RISDESC# - Riser description, applies to connected spraylines only.
#RISLABEL# - Riser label, applies to connected spraylines only.
#TYPE# - Pipe type, applies to pipes and tapes only.
#UID# - Internal unique ID for item.
#DEPTH# - depth of item, applies only to pipes, tapes, wires.
#DEPTHUNIT# - Current unit of depth
These labels are specific to block entities only (Spray Irrigation Block and Tape Irrigation Block)
#AREA# - Total plan area within block boundary.
#IRRAREA# - Normally the total length of laterals (2D) * lateral spacing, see below under “Crop Width”.
#LATSPACE# - Lateral spacing.
#NUMLAT# - Number of lateral segments.
#NUMROW# - Number rows or laterals.
#TOTLATLEN# - Total 3D length of laterals (calculated with slope method).
#NOMPRESS# - Nominal Inlet pressure of Tape laterals.
#NOMFLOW# - Block flow based on nominal SDR from database.
#MAXINTENS# - Maximum allowable intensity.
#H2OQUANT# - Water requirements either volume or depth.
#AREAUNIT# - current area unit.
#PRESSUNIT# - current pressure unit.
#FLOWUNIT# - current large (sys flow/zone) flow unit.
#DESC# - When used in a block displays the description of the Tape.
#ACTFLOW# - The flow for the block as calculated during the design process. If the design is incomplete, then the nominal flow is displayed.
#SHIFT# - lists the system flows that the block operates in.
#MINEMITPRESS# - The minimum emitter pressure in the block, from design.
#MAXEMITPRESS# - The maximum emitter pressure in the block, from design.
#MEANPRESS# - The mean tape inlet pressure in the block.
#VALVEPRESS# - The calculated downstream pressure for the control valve attached to the block.
Keywords for Labels
- jovivier
- Site Admin
- Posts: 919
- Joined: Thu Mar 12, 2009 2:57 pm
- Company: Lincoln Agritech Ltd, IRRICAD Software
- City / Town: Lincoln
- Location: Canterbury, New Zealand
- Contact:
Re: Keywords for Labels
New keywords were added to Pro version 10. These can be found in the Manual or Online Help - Help|Help Topics Technical Reference Appendix I: Label Keywords.
These keywords are also now available from a drop-down combo box in the Label Text Settings, however, to determine if a keyword can only be used for Irrigation Block Entities, refer to the manual as mentioned above.
These keywords are also now available from a drop-down combo box in the Label Text Settings, however, to determine if a keyword can only be used for Irrigation Block Entities, refer to the manual as mentioned above.