i have attached an example of a new area that i think will add some usability to the Tape/Spray block entity.
under the block tab of the dialogue box i suggest putting a section for multiple submain sizes, using the percent feature which is used for valve location. most of the time as a designer you already know approx what is going to be the submain sizes used. for example - a submain of 100m in length. we could split the sub into three equal parts, ie 33% in each drop down menu. when you have a starting point that is closer to your end submain sizes, only minor tweaking is then needed to finish the submain design.
Suggestions for - Tape/Spray Block Entity
Suggestions for - Tape/Spray Block Entity
You do not have the required permissions to view the files attached to this post.
- Gennaro Vellotti
- Posts: 51
- Joined: Wed Oct 14, 2009 3:28 pm
- Company: Netafim Australia & New Zealand
- City / Town: Adelaide
- Location: Adelaide, Australia
- Contact:
Re: Suggestions for - Tape/Spray Block Entity
Another good idea, would certainly save time on medium to large designs, afterall time is money. 

Gennaro Vellotti
Irrigation Engineer Lead
Netafim Australia/NZ
+61 419 362 845
Irrigation Engineer Lead
Netafim Australia/NZ
+61 419 362 845
- Kosi Kalogerinis
- Posts: 69
- Joined: Fri Oct 23, 2009 3:56 pm
- Company: Netafim Australia
- City / Town: Adelaide, South Australia
- Product: Irricad Link (BricsCAD)
Re: Suggestions for - Tape/Spray Block Entity
May I add another suggestion closely related to that?
What about an additional check box which would round off submain pipe lengths as close as possible to a multiple of 6m?
What about an additional check box which would round off submain pipe lengths as close as possible to a multiple of 6m?

- Kosi Kalogerinis
- Posts: 69
- Joined: Fri Oct 23, 2009 3:56 pm
- Company: Netafim Australia
- City / Town: Adelaide, South Australia
- Product: Irricad Link (BricsCAD)
Re: Suggestions for - Tape/Spray Block Entity
Would be good to see this in future releases 

- Gennaro Vellotti
- Posts: 51
- Joined: Wed Oct 14, 2009 3:28 pm
- Company: Netafim Australia & New Zealand
- City / Town: Adelaide
- Location: Adelaide, Australia
- Contact:
Re: Suggestions for - Tape/Spray Block Entity
BUMP
BUMP
BUMP
Gennaro Vellotti
Irrigation Engineer Lead
Netafim Australia/NZ
+61 419 362 845
Irrigation Engineer Lead
Netafim Australia/NZ
+61 419 362 845
- Kosi Kalogerinis
- Posts: 69
- Joined: Fri Oct 23, 2009 3:56 pm
- Company: Netafim Australia
- City / Town: Adelaide, South Australia
- Product: Irricad Link (BricsCAD)
Re: Suggestions for - Tape/Spray Block Entity
BUMP
I am pretty sure every Irricad user would love to have this.
From the end of the submain,
Select size 1- user to input number of metres
Select size 2- user to input number of metres
Select size 3- user to input number of metres or balance to valve
And for it to add a pipe junction between sizes exactly at the specified metre mark (ie not a size change at an existing row close to the metre mark)
I am pretty sure every Irricad user would love to have this.
From the end of the submain,
Select size 1- user to input number of metres
Select size 2- user to input number of metres
Select size 3- user to input number of metres or balance to valve
And for it to add a pipe junction between sizes exactly at the specified metre mark (ie not a size change at an existing row close to the metre mark)
- Kosi Kalogerinis
- Posts: 69
- Joined: Fri Oct 23, 2009 3:56 pm
- Company: Netafim Australia
- City / Town: Adelaide, South Australia
- Product: Irricad Link (BricsCAD)
Re: Suggestions for - Tape/Spray Block Entity
I can't wait for something like thisKosi Kalogerinis wrote: ↑Thu May 16, 2019 12:54 pm BUMP
I am pretty sure every Irricad user would love to have this.
From the end of the submain,
Select size 1- user to input number of metres
Select size 2- user to input number of metres
Select size 3- user to input number of metres or balance to valve
And for it to add a pipe junction between sizes exactly at the specified metre mark (ie not a size change at an existing row close to the metre mark)