INPUT 82

If your question does not belong in any of the other forums, then this is the forum for you.
Post Reply
Miguel_l_e
Posts: 63
Joined: Thu Feb 05, 2015 7:00 am
Company: indep
City / Town: Guayaquil

INPUT 82

Post by Miguel_l_e »

I get this message and valves too large

"Warning, coordinate range too large please correct and then run compress"

help
-----------------------------
Miguel Loaiza Espinoza
Irrigation Designer
Mloaiza@magap.gob.ec
Mloaiza06@gmail.com
Mob +593-989842755
User avatar
Dan Crosby
Site Admin
Posts: 181
Joined: Thu Apr 30, 2009 9:28 am
Company: Lincoln Agritech Ltd.
City / Town: Lincoln
Location: Lincoln, New Zealand
Contact:

Re: INPUT 82

Post by Dan Crosby »

Hi Miguel,

You will get this message in one of two situations, usually after importing data. It appears when you have entities that are more than approximately 12.5km apart in your design. Sometimes when importing DXF/DWG there is some 'junk' far removed from your area of interest - View|Zoom All will show this. In that case, select and delete the 'junk' then run File|Compress.

(Note, it is sometimes easier to first select all the entities you do want to keep, then use Modify|Invert Selection to select everything you want to get rid of).

Alternatively, your design may legitimately be larger than ~12.5km in which case you can ignore this message.

Regards,

Dan

Dan Crosby
Irricad Developer
Lincoln Agritech Ltd
Miguel_l_e
Posts: 63
Joined: Thu Feb 05, 2015 7:00 am
Company: indep
City / Town: Guayaquil

Re: INPUT 82

Post by Miguel_l_e »

I did zoom all, but I can not find any junk on Irricad or the dxf file, besides Valve size becomes too large.

thanks for answer
-----------------------------
Miguel Loaiza Espinoza
Irrigation Designer
Mloaiza@magap.gob.ec
Mloaiza06@gmail.com
Mob +593-989842755
User avatar
jovivier
Site Admin
Posts: 919
Joined: Thu Mar 12, 2009 2:57 pm
Company: Lincoln Agritech Ltd, IRRICAD Software
City / Town: Lincoln
Location: Canterbury, New Zealand
Contact:

Re: INPUT 82

Post by jovivier »

Miguel,
For priority Version 14 support you can contact your local IRRICAD distributor. They may wish to see your design to help locate the items, which could be located on layers that are currently turned off. Once these have been removed and File|Compress has been run resize the symbols to a different size and then back to the correct size.
See also the Support FAQ Forum for the warning message http://www.irricad.com/phpbb3/viewtopic.php?f=17&t=420.