The units are as you put them
it seems that you have a problem with the heights in your system
Try to run the 3D DEM view in order to check were is the elevation problematic point
Search found 13 matches
- Sat Sep 21, 2024 5:26 pm
- Forum: Hydraulic Design
- Topic: Headloss units
- Replies: 2
- Views: 831
- Sat Dec 02, 2023 7:04 pm
- Forum: Bug Reports
- Topic: New Version V21.10
- Replies: 1
- Views: 2280
New Version V21.10
It seems that there is a problem with the Label of the Hydraulic items or maybe Database
Instead of #LABEL@ for pipe we get *****
Please correct ASAP
Instead of #LABEL@ for pipe we get *****
Please correct ASAP
- Wed Sep 06, 2023 5:33 pm
- Forum: Hydraulic Design
- Topic: Calculo de Perda de Pressão, Irricad x Excel
- Replies: 7
- Views: 5962
Re: Calculo de Perda de Pressão, Irricad x Excel
Hi Mr. Oliviera from what I checked in example with your data I get very similar results that you show in the HydroCalc application But when I checked your example from the report it is not with the same sections of pipe diameter lengths between 100mm , 75mm , 50mm & 35mm . I suggest that you wi...
- Fri Feb 23, 2018 9:31 pm
- Forum: Miscellaneous
- Topic: Elevation Labels
- Replies: 1
- Views: 6187
Re: Elevation Labels
In the Label Table use .
Write the Layer for the Contour as Elevations
Write the Layer for the Contour as Elevations
- Tue Feb 03, 2015 5:24 am
- Forum: Hydraulic Design
- Topic: Lateral pipe sizes in Spray Blocks
- Replies: 3
- Views: 8562
Re: Lateral pipe sizes in Spray Blocks
I assume it is more than 10 years there
- Mon Feb 02, 2015 8:55 am
- Forum: Hydraulic Design
- Topic: Lateral pipe sizes in Spray Blocks
- Replies: 3
- Views: 8562
Re: Lateral pipe sizes in Spray Blocks
You can use the tool "Move Sizes"
Create the line 100m from the submain and arrange according the 32mm pipe
Create the line 100m from the submain and arrange according the 32mm pipe
- Mon Jan 27, 2014 5:20 pm
- Forum: Miscellaneous
- Topic: Changing Area Names / Valve Names
- Replies: 2
- Views: 5991
Re: Changing Area Names / Valve Names
The need for it is in the cases that we want names for the irrigation areas where it is according to the client names and we want the name of the Valve will be the same as the irrigation area and the change of the name is not from the start of the creating of area. In such cases if it is posible to ...
- Wed Apr 17, 2013 3:53 am
- Forum: Reports
- Topic: Zone Design Summary Report - not updating change
- Replies: 2
- Views: 9901
Re: Zone Design Summary Report - not updating change
Is there a reason why the Zone Design Summary Report will not show the correct flow for a zone when I have changed the valve pressure on the zone? It seems that I can do the initial zone design with a given tape and pressure and get what seems to be the correct flow. When I change the valve pressur...
- Thu Oct 11, 2012 3:26 am
- Forum: Hydraulic Design
- Topic: Drip Lines Design
- Replies: 5
- Views: 9558
Re: Drip Lines Design
Hi Rafat If the situation that you have is that you use only 2 drippers per tree (it seems to be not enough for the arid area -except it is at least 24 lph each) you can create a special tape where the flow that you are using per tree is twice the dripper flow with 8m spacing . With the way that Kos...
- Fri May 18, 2012 3:26 am
- Forum: Hydraulic Design
- Topic: Diameters
- Replies: 4
- Views: 9139
Re: Diameters
Hi Patricio From the way the Zone Pipes changes the diameters & the contour lines it means that you use the LP DESIGN . Check what is the Velocity in the cut pipe before you go to the bigger diameter . Check the pressure that you get at the Valve in the Zone Design Configuration . In the Design ...
- Tue Jul 26, 2011 2:34 am
- Forum: Reports
- Topic: Total Zone Flow in Zone Summary Report
- Replies: 4
- Views: 14160
Re: Totla Zone Flow in Zone Summary Report
Hi The Zone Summary Report gives your the Right answer. In the Management report or in the System flows at this stage it take into account the default flow from the SDR data . Your PC dripper has some difference in flow along the range of pressure so it create about an average of around 1%-2% lower ...
- Fri Apr 22, 2011 3:58 pm
- Forum: Suggestions
- Topic: Pipe reduction symbol
- Replies: 16
- Views: 29987
Re: Pipe reduction symbol
Hi All
I agree with Matt's suggestion . No need for more than 1 symbol . In any other case of Tee or Cross - It is clear to the installer he should put something and the same if it is any other hydraulic Item .
Regards
Gilary
I agree with Matt's suggestion . No need for more than 1 symbol . In any other case of Tee or Cross - It is clear to the installer he should put something and the same if it is any other hydraulic Item .
Regards
Gilary
- Thu Mar 31, 2011 4:33 pm
- Forum: Miscellaneous
- Topic: Creating a new line style
- Replies: 3
- Views: 7945
Re: Creating a new line style
Hi Dan
Can you create a line style that include text as example
------x------x------x
Regards
Gilary
Can you create a line style that include text as example
------x------x------x
Regards
Gilary