Search found 18 matches

by Jim Phillips
Thu Jan 17, 2019 2:09 pm
Forum: Hydraulic Design
Topic: Mainline pipes not joining in IrriCAD Link
Replies: 1
Views: 6383

Mainline pipes not joining in IrriCAD Link

I am experiencing a problem in an IrriCAD Link design. Design is laid out normally but the mainline pipes won't connect. Any thoughts?
by Jim Phillips
Mon Oct 30, 2017 12:10 pm
Forum: CAD Drawing
Topic: CROSSHAIRS AT 45 DEGREES
Replies: 3
Views: 13163

Re: CROSSHAIRS AT 45 DEGREES

Thanks, Toggling and IM have worked a treat.
by Jim Phillips
Thu Oct 19, 2017 6:49 pm
Forum: CAD Drawing
Topic: CROSSHAIRS AT 45 DEGREES
Replies: 3
Views: 13163

CROSSHAIRS AT 45 DEGREES

My crosshairs suddenly went from 90 degrees on the screen to 45 degrees and acted orthographically. how do I turn this off?
by Jim Phillips
Sat Sep 02, 2017 7:57 pm
Forum: Hydraulic Design
Topic: Assign Zones to Water supplies
Replies: 1
Views: 6388

Assign Zones to Water supplies

In a large design I am having trouble getting IrriCAD to select the zones I want for a given water supply. It works up so far then keeps defaulting the previous allocate zone to zero. Is there a way to nominate in the "Assign Zones to System Flows" box to enter say Zones 1 - 30 on Water Su...
by Jim Phillips
Thu Oct 01, 2015 10:58 am
Forum: Reports
Topic: Zone Flush Reports
Replies: 0
Views: 8894

Zone Flush Reports

Hi Jo, Can IrriCAD generate a report on Zone Flushing that is a collation of all of the analysis of the manifold flushing reports. As I do the individual manifold analysis, the data for that manifold comes up in the Zone Flushing Report. Once I do a manifold I save it so that I can refer to it at a ...
by Jim Phillips
Wed Mar 11, 2015 6:35 pm
Forum: CAD Drawing
Topic: Labelling of pipework
Replies: 2
Views: 11804

Re: Labelling of pipework

Thanks Dan
by Jim Phillips
Thu Feb 19, 2015 4:47 pm
Forum: CAD Drawing
Topic: Labelling of pipework
Replies: 2
Views: 11804

Labelling of pipework

How can I label a section of pipe so that the label is inclined 45 degrees to the line of the pipe? I used to be able to do in in Settings, labels etc but this does not appear to work anymore.
by Jim Phillips
Thu Jan 01, 2015 12:40 pm
Forum: Hydraulic Design
Topic: Co-ordinates
Replies: 0
Views: 6055

Co-ordinates

Thanks to Gennaro for solving a problem for me on New Years eve. I had imported a dwg, (big co-ordinate numbers) file in to IrriCAD and not corrected my x/y co-ordinates in IrriCAD. The effect of this on IrriCAD was dramatic, I thought I had a virus, total chaos. Note to self to always check co-ordi...
by Jim Phillips
Thu Jan 01, 2015 12:32 pm
Forum: Hydraulic Design
Topic: Creating Spray Entities from individually placed outlets & v
Replies: 2
Views: 7405

Creating Spray Entities from individually placed outlets & v

I am doing a unusually shaped landscape design that requires me to individually place sprinklers and valves. In doing this I am also manually selecting the zones for flow and location. This all calculates well with no problems. What I would like to be able to access is the "Management Report&qu...
by Jim Phillips
Sat Aug 16, 2014 1:23 pm
Forum: Miscellaneous
Topic: AVIS2D.ocx Error
Replies: 1
Views: 6322

AVIS2D.ocx Error

IrriCAD13 is driving me nuts. It has worked great for about 6 months, bit unstable but manageable. I am using Windows 8.1 and in the last week have had some major issues. The ute file vanished. Today it is the above AVIS2D.ocx. I have tried the memo from Jo to no avail. What is going on? I have unin...
by Jim Phillips
Wed Aug 13, 2014 4:11 pm
Forum: Hydraulic Design
Topic: Negative mainline pressures
Replies: 1
Views: 6446

Negative mainline pressures

I have a design with a 75 metre variation in elevation. not all in one block but spread out over a range of blocks. The most a single bloc falls is about 15 metres. The zone design fits into the pressure parameters quite well (PC design)in velocity design and having multiple lateral and submain size...
by Jim Phillips
Mon Jun 30, 2014 9:46 am
Forum: Hydraulic Design
Topic: LP Desogn and Analyze Zone give different results
Replies: 2
Views: 6957

LP Desogn and Analyze Zone give different results

I am doing a park pop up design. I am working my way through the various differing turf and garden areas one at a time and as I locate the sprinklers, connect them up I then add them to the zone count. (Assign System Flows) I then do an LP design, Valve analysis and a mainline design and get a good ...
by Jim Phillips
Wed Nov 13, 2013 3:33 pm
Forum: Hydraulic Design
Topic: Multiple Water Supplies
Replies: 2
Views: 6773

Re: Multiple Water Supplies

Thanks Jo, have got it working with a bit of input from Kosi.

Rgds

Jim P :
by Jim Phillips
Thu Nov 07, 2013 7:43 pm
Forum: Hydraulic Design
Topic: Multiple Water Supplies
Replies: 2
Views: 6773

Multiple Water Supplies

I am doing a design with 3 independent water supplies. How do I enter the data to have n*IrriCAD size each mainline and sytem duty. The mains are not connected to each other, all supply their own zones
by Jim Phillips
Tue Jan 08, 2013 1:19 pm
Forum: Bug Reports
Topic: v11.12 Reinstall problen
Replies: 3
Views: 11371

Re: v11.12 Reinstall problen

Thanks Kosi and Jo, I am away and wont be back until Friday however, I have tried the compatibility mode without success. When I get back I will try the solution suggested by Kosi. In answer to your questions Jo, I can copy and send the "unexpected problem" report. Yes, once I have re-inst...
by Jim Phillips
Mon Dec 17, 2012 9:45 am
Forum: Bug Reports
Topic: v11.12 Reinstall problen
Replies: 3
Views: 11371

v11.12 Reinstall problen

Hi Jo, Having a bit of grief with the Winicad.exe file. My power supply died a few weeks ago, had it replaced, all good. The problem is that when I go to open IrriCAD a message comes up saying IrriCAD has encountered an unexpected problem and needs to shut down. By uninstalling and re-installing Irr...